LM25066I, LM25066IA
www.ti.com
SNVS824C –JUNE 2012–REVISED MARCH 2013
Intel Node Manager Compliant System Power Management and Protection IC with PMBus
Check for Samples: LM25066I, LM25066IA
1
FEATURES
DESCRIPTION
While the LM25066I/A is functionally similar to the
LM25066/A, the LM25066I/A is fully compliant to Intel
Node Manager 2.0, 2.5 and adds the READ_EIN
energy accumulator feature. The LM25066I/A
combines a high-performance hot-swap controller
with a PMBus 1.2™ compliant SMBus/I2C interface to
accurately measure, control and protect the electrical
operating conditions of critical systems. The
LM25066I/A continuously supplies real-time power,
voltage, current, temperature, and fault data to the
system management host via the SMBus interface.
2
•
Fully Node Manager 2.0 and 2.5 Compliant with
I2C/SMBus interface and PMBus™ compliant
command structure
•
•
Input voltage range: 2.9V to 17V
Programmable 25mV or 46mV current limit
threshold
•
•
•
•
•
Read_EIN accurately measures true input
power via simultaneous sampling
Configurable circuit breaker protection for
hard shorts
The LM25066I/A control block includes a unique hot-
swap architecture that provides current and power
limiting to protect sensitive circuitry even during the
most stressful conditions. A fast-acting circuit breaker
prevents damage in the event of a short circuit on the
output. The input under-voltage, over-voltage
hysteresis, insertion delay time and fault detection
time are all configurable. A temperature monitoring
block on the LM25066I/A interfaces with a low-cost
Configurable under- and over-voltage lockouts
with hysteresis
Real time monitoring of VIN, VOUT, IIN, PIN, VAUX
with 12-bit resolution and 1 kHz sampling rate
Current measurement accuracy: ±1%
(LM25066IA) and Power measurement
accuracy: ±2.0% (LM25066IA) over temperature
•
Averaging of VIN, IIN, PIN, and VOUT over
programmable interval ranging from 0.001 to 4
seconds
external
diode
for
continuous
temperature
assessment of the external MOSFET or other thermal
sensitive components. The POWER GOOD output
provides a fast alert when the input and/or output
voltages are outside their programmed range.
Accurate power readings are accomplished by using
•
•
Programmable WARN and FAULT thresholds
with SMBA notification
Blackbox capture of telemetry measurements
and device status triggered by WARN or
FAULT condition
the
READ_EIN
command.
A
black
box
(Telemetry/Fault Snapshot) function captures and
stores telemetry data and device status in the event
of a warning or a fault.
•
24-lead WQFN package
APPLICATIONS
•
•
•
Server backplane systems
Basestation power distribution systems
Solid state circuit breaker (eFuse)
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2
All trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.