High Surge Current (D-rated) SIDACtor® Device
RoHS
¨
DO-214AA SIDACtor solid state protection devices with a D surge rating protect
telecommunications equipment located in hostile environments. These SIDACtor devices
withstand the simultaneous surges outlined in GR 1089 lightning tests. (See “First Level
Lightning Surge Test” on page 7-5.) Surge ratings are twice that of a device with a C surge
rating. This provides a method for building an SMT version of the balanced ‘Y’ configuration.
(US Patent 4,905,119) SIDACtor devices enable equipment to comply with various
regulatory requirements including GR 1089, ITU K.20, K.21 and K.45, IEC 60950,
UL 60950, and TIA-968-A (formerly known as FCC Part 68).
Electrical Parameters
Part
V
DRM
V
V
I
I
S
I
T
I
H
S
T
DRM
Number *
Volts
Volts
Volts
µAmps
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
Amps **
mAmps
P0080SDL
P0640SDL
P0720SDL
P0900SDL
P1100SDL
P1300SDL
P1500SDL
P1800SDL
P2300SDL
P2600SDL
P3100SDL
P3500SDL
6
25
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
2
50
58
77
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
50
65
88
50
75
98
50
90
130
160
180
220
260
300
350
400
50
120
140
170
190
220
275
320
50
50
50
50
50
50
50
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
** The 2.2 A version cannot be used to meet 4.4 A requirements.
General Notes:
•
•
•
•
•
•
All measurements are made at an ambient temperature of 25 °C. I applies to -40 °C through +85 °C temperature range.
PP
I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
V
V
is measured at I
DRM.
is measured at 100 V/µs.
DRM
S
Special voltage (V and V
) and holding current (I ) requirements are available upon request.
DRM H
S
Surge Ratings in Amps
I
PP
0.2x310 * 2x10 *
8x20 *
10x160 * 10x560 * 5x320 * 10x360 * 10x1000 * 5x310 *
I
TSM
0.5x700 ** 2x10 ** 1.2x50 ** 10x160 ** 10x560 ** 9x720 ** 10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
di/dt
Amps/µs
1000
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
D
—
—
1000
—
—
—
—
200
—
50
* Current waveform in µs
** Voltage waveform in µs
www.littelfuse.com
3 - 10
© 2006 Littelfuse • Telecom Design Guide