LH40 SERIES
40W, AC-DC CONVERTER
LH40series---- converter offered by Mornsun. It features universal input voltage,
taking both DC and AC input voltage, high efficiency, high reliability, low power
consumption and safer isolation. It offers good EMC performance, certificate
IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and is
widely used in industrial, office and electricity applications. For harsh EMC
environment, the application circuit in the datasheet is strongly recommended.
RoHS
PRODUCT FEATURES
PART NUMBER SYSTEM
LH40-10B03
1. Universal input range:85~264VAC/120~370VDC
2. AC and DC all in one (input from the same terminal)
3. Low standby power consumption, high efficiency,3000VAC
safe isolation
4. Low ripple and noise
5. Protection of output short circuit, over-current, over-voltage
6. Perfect EMC performance
7. Meet IEC61000, UL60950and IEC60950 standards
8. 3 years product warranty
SELECTION GUIDE
Rippl
Standby
Power
Consumption
(Max.)
Max.
Capacitive
Load
Efficiency
(230VAC,
Typ.)
e and
Noise
(Typ.)
Model
Package
Power
26.4W
Output (Vo1/Io1)
Output (Vo2/Io2)
LH40-10B03
LH40-10B05
3.3VDC/8000mA
5VDC/8000mA
9VDC/4444mA
12VDC/3333mA
15VDC/2666mA
24VDC/1667mA
5VDC/5000mA
5VDC/5000mA
+5VDC/4000mA
+12VDC/1666mA
+15VDC/1333mA
5VDC/5000mA
5VDC/5000mA
--
--
--
--
--
60000 uF
40000 uF
12000 uF
9000 uF
7000 uF
2000 uF
10000/470 uF 50mV
10000/400 uF
±12000 uF
78%
82%
84%
84%
84%
84%
82%
82%
82%
84%
84%
82%
82%
LH40-10B09
LH40-10B12
LH40-10B15
LH40-10B24
--
LH40-10D0512-13
*LH40-10D0524-06
*LH40-10A05
LH40-10A12
89.0*63.5*25.0mm
12VDC/1250mA
0.5W
40W
24VDC/625mA
-5VDC/4000mA
-12VDC/1666mA
-15VDC/1333mA
±12VDC/600mA
±15VDC/500mA
±4400 uF
*LH40-10A15
*LH40-10C0512-06
*LH40-10C0515-05
Note:*Designing
±1000 uF
10000/±780 uF
10000/±900 uF
INPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
264
370
440
1.0
0.6
--
Unit
V
AC Input
DC Input
85
120
47
--
--
--
Input Voltage Range
Input Frequency
Input Current
--
Hz
115VAC Input
230VAC Input
--
--
--
A
115VAC Input
230VAC Input
--
30
50
Inrush Current
--
--
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
±2
Max.
--
Unit
%
Output Voltage Accuracy
LH40-10BXX
LH40-10AXX
LH40-10DXX
Main output
--
--
--
Main output / Secondary output
Main output
±2
--
±2
--
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LH40 series 2013.08.28-A/1 Page 1 of 5