AC/DC Converter
LH15-20BxxMU Series
15W, AC-DC converter
FEATURES
Universal Input : 85 - 264VAC, 100 - 370VDC, 50/60Hz
Regulated output , Low ripple & noise
Low no-load power consumption < 0.1W
High efficiency up to 86%
Output short circuit, over-current, over-voltage
protection
Meets EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1 standards
(2xMOPP)(Pending)
Mounting: PCB mounting, Chassis mounting,
DIN-Rail mounting available
Meets 5000m altitude requirements
RoHS
LH15-20BxxMU series ----- is a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC
Input voltage, low power consumption, high efficiency, high reliability, safer isolation. Meets EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1 standards (2xMOPP), and widely used in medical, industrial, instruments, telecommunication and civil
applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended.
Selection Guide
Certification
Nominal Output Voltage and
Current(Vo/Io)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive
Load(µF)
Part No.
Output Power
14W
LH15-20B05MU
LH15-20B12MU
LH15-20B15MU
LH15-20B18MU
LH15-20B24MU
5V/2800mA
12V/1250mA
15V/1000mA
18V/833mA
24V/625mA
78
83
83
84
86
8000
4000
3000
2000
800
CSA/CE
(Pending)
15W
Input Specifications
Item
Operating Conditions
AC input
Min.
85
100
47
--
Typ.
--
Max.
264
370
440
0.37
0.22
--
Unit
VAC
VDC
Hz
Input Voltage Range
Input frequency*
Input current
--
DC input
--
--
115VAC
230VAC
115VAC
230VAC
--
--
A
10
--
Inrush current
--
20
--
0.1mA RMS typ./264VAC/60Hz
2A/250V, slow fusing
Unavailable
Leakage current
Recommended External Input
Fuse(Special package series include fuse)
Hot Plug
*Medical Certification Input frequency range:47-63 Hz
Output Specifications
Item
Operating Conditions
Min.
--
Typ.
±2
Max.
--
Unit
%
Output Voltage Accuracy
Main circuit
Full load
--
±0.5
±1
--
Line Regulation
--
--
Load Regulation
Ripple & Noise*
--
50
100
--
mV
20MHz bandwidth (peak-peak value)
--
±0.02
%/°C
Temperature Coefficient
2016.09.13-A/0
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation