Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
10
F
-O -O
5 6
LFA10F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA10F-3R3-Y
6.6
LFA10F-5
10
LFA10F-12
10.8
LFA10F-15
10.5
LFA10F-24
12
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 2A
5V 2A
12V 0.9A
15V 0.7A
24V 0.5A
SPECIFICATIONS
MODEL
LFA10F-3R3-Y
LFA10F-5
LFA10F-12
LFA10F-15
LFA10F-24
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.18typ (Io=100%)
0.26typ (Io=100%)
0.16typ (Io=100%)
CURRENT[A]
ACIN 200V 0.11typ (Io=100%)
50 / 60 (47 - 440)
FREQUENCY[Hz]
INPUT
ACIN 100V 68.0typ
74.0typ
76.0typ
76.5typ
79.0typ
77.5typ
80.0typ
79.5typ
83.0typ
EFFICIENCY[%]
ACIN 200V 68.5typ
ACIN 100V 15typ (Io=100%)
ACIN 200V 30typ (Io=100%)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
CURRENT[A]
2.0
2.0
0.9
0.7
0.5
*
5
5
20max
40max
20max
40max
80max
140max
160max
120max
160max
240max
50max
60max
20max
48max
100max
120max
160max
240max
150max
180max
300max
120max
150max
48max
60max
120max
120max
160max
240max
150max
180max
300max
150max
180max
60max
96max
150max
120max
160max
280max
150max
180max
320max
240max
290max
96max
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
0 to +50C 80max
-10 - 0C 140max
Io=0 - 35% 190max
0 to +50C 120max
-10 - 0C 160max
Io=0 - 35% 240max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
RIPPLE NOISE[mVp-p]
OUTPUT
*1
TEMPERATURE REGULATION[mV]
*2
20max
DRIFT[mV]
START-UP TIME[ms]
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
27.60 to 33.60
Works over 105% of rating and recovers automatically
4.00 to 5.25
Not provided
Not provided
Not provided
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION
INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*6
*4
(Not built-in to active filter)
Complies with IEC61000-3-2 (Class A)
50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (with chassis & cover : 150g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
factor Io=0-35% is different.
Please contact us for details.
Please refer to the Instruction Manual 1.7.
Drift is the change in DC output for an eight hour period after
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
*5
*6
*
Please contact us about dynamic load and input response.
Please contact us about another class.
*2
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
*
*3
*4
Derating is required.
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
load.
When two or more units are operating it may not comply with
the IEC61000-3-2.
*
LFA-2