Series
LF200ES
Low Cost, 2W SMT
Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 2W Output Power
Conditions
Min.
Typ.
5.0
Max.
5.5
Units
VDC
A
5 VDC Input
4.5
• Ultra-Miniature SMT Case
• 1,000 VDC Isolation
Input Voltage Range
12 VDC Input 10.8
Capacitor
12.0
13.2
1.0
Reverse Polarity Input Current
Input Filter
• -40ºC to +85ºC Operation
• Single Output
• Low 0.24” Profile
Output
• >3.5 MHour MTBF
• Industry Standard Pin-Out
• LOWEST COST!
Parameter
Conditions
Min.
Typ.
Max.
Units
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Output Ripple (20 MHz)
Output Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
3.0
For Vin Change of 1%
For Iout = 10% to 100%
1.2
15
%
8
75
%
150
250
0.03
mV P - P
mV P - P
%/ºC
150
Momentary (0.5 Sec.)
Parameter
Conditions
Conditions
Min.
60 Seconds 1,000
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M⍀
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
70
100
kHz
Min.
Typ.
Max.
+85
Units
ºC
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
-40
-55
+25
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
0.70 x 0.72 x 0.24 Inches (17.78 x 18.03 x 6.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.05 Oz (1.5g)
Case Material
Weight
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
MHours
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Max.
7.0
Units
5 VDC Input -0.7
12 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
15.0
260.0
450
Lead Temperature
1.5 mm From Case For 10 Sec
All Models
ºC
Internal Power Dissipation
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com