APPLICABLE STANDARD
-25 C TO
+85 C
-10
C TO
+60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 30 V , DC 42 V
2 A
WIRE SIZE
CURRENT
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
ELECTRIC CHARACTERISTICS
X
X
X
X
X
X
15 m MAX.
1000 M MIN.
CONTACT RESISTANCE
INSULATION RESISTANCE
VOLTAGE PROOF
CONTACT SHALL BE MEASURED AT DC
1
A
100
300
V DC.
V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
φ0.53 ± 0.003 BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES : 0.15 N MIN.
INSERTION AND WITHDRAWAL FORCES
X
X
-
-
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR
WITHOUT LOCKING DEVICE.
LOCKING DEVICE WITH UNLOCK
: 50 N MAX.
- N MAX.
m MAX.
①NO ELECTRICAL DISCONTINUITY OF 10 s.
LOCKING DEVICE WITH LOCK
:
X
X
-
-
CONTACT RESISTANCE:
30
MECHANICAL OPERATION
VIBRATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
FREQUENCY: 10 → 55 → 10 (Hz) (1CYC,5min),
SINGLE AMPLITUDE 0.75 mm, AT 10 CYC,FOR 3 DIRECTIONS. ②NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
SHOCK
IN OPPOSITE DIRECTIONS OF EACH 3 DIMENSION AXIS FOR 3
TIMES AT 490 m/s2 DURATIONS OF PULSE 11 ms.
X
X
-
-
BREAKING STRENGTH
MAX 100 N SHALL BE APPLIED TO CABLE IN UP AND
DOWN,LEFT AND RIGHT DIRECTIONS WHEN MATED.
NO BREAKAGE MAX 100N.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
X
-
(STEADY STATE)
② INSULATION RESISTANCE: 100 MΩ MIN
(AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 100 MΩ MIN..
RAPID CHANGE OF TEMPERATURE TEMPERATURE -55→ R/T(1) → +85 → R/T ℃
X
-
TIME 30 → 2 TO 3 → 30 → 2 TO 3 min UNDER 5 CYCLES. ② NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
X
X
X
-
-
-
EXPOSED IN 5 SALT WATER SPRAY FOR 48 h.
EXPOSED AT + 85 ℃,96 h.
CORROSION SALT MIST
NO HEAVY CORROSION RUIN THE FUNCTION.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
DRY HEAT
EXPOSED AT – 55 ℃,96 h.
COLD
RESISTANCE TO SOLDERING
HEAT
PLACE SOLDERING IRON(IRON TIP TEMPERATURE +350±10℃) NO DEFORMATION OF CASE OF EXCESSIVE LOOSENESS
AND SOLDER TO DIP AREA FOR 5±1 s. OF THE TERMINALS.
X
-
SOLDERABILITY
PLACE SOLDERING IRON(IRON TIP TEMPERATURE +350±10℃) A SOLDERING SIDE IS TO BE WET WITH SOLDER.
X
X
-
-
AND SOLDER TO DIP AREA FOR 2 TO 3 s.
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
AND, NO SMALL LUMP OF THE SOLDER.
SEALING
NO WATER PENETRATION INSIDE CONNECTOR.
AIR TIGHTNESS
APPLY AIR PRESSURE 17.6kPa FOR 0.5min TO INSIDE
CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR.
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
NOTES(1)R/T : ROOM TEMPERATURE
APPROVED
CHECKED
DESIGNED
EJ.KUNII
EJ.KUNII
16.10.03
16.10.03
16.09.30
(2)SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER MATED CONDITION WITH
AN APPLICABLE CONNECTOR.
SJ.SHIMIZU
DRAWN
SY.KONDO
16.09.30
Unless otherwise specified, refer to IEC60512(JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-119581-00-00
LF13WBRB-20SD
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL136-1027-0-00
FORM HD0011-2-1