APPLICABLE STANDARD
Operating
Storage Temperature
Range
-25C to +85C
-10C to +60C
Temperature Range
26 to 30 AWG
Insulation outside diameterφ1 MAX
AC 30 V, DC 42 V
2A
Wire Size
Rating
Voltage
Current
Applicable Cable
-
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
-
-
Contact Resistance
Insulation Resistance
Measured at DC 1A.
30 m MAX.
Measured at 100 V DC.
1000 M MIN.
Voltage Proof
300 V AC applied for 1 min.
No breakdown.
X
-
MECHANICAL CHARACTERISTICS
Contact Insertion and
Extraction Forces
Measured with a φ5.3 ± 0.003 steel gauge.
Insertion and extraction forces: 0.15 N MIN.
Insertion and withdrawal forces : 50 N MAX.
X
X
-
-
Connector Insertion and
Withdrawal Forces
Measured with an applicable connector.
(Without lock)
Mechanical Operation
Mated and unmated 1000 times.
Contact resistance: 50 m MAX.
X
X
-
-
Vibration
Frequency: 10 Hz to 55 to 10 Hz every cycle (5 min per
1) No electrical discontinuity of more than 10 s.
cycle)
2) No damage, cracks or looseness of parts.
Single amplitude: 0.75 mm
Performed over 10 cycles in each of three mutually
perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
1) No electrical discontinuity of more than 10 s.
Performed 3 times in each of three mutually perpendicular
directions.
2) No damage, cracks or looseness of parts.
X
-
Breaking Strength
Force is applied to the plug body in up, down,
left and right directions while mated.
No breakage at 100 N.
X
X
-
-
Contact Retention Force
Applying a pull force the wire after the applicable
crimped contact is assembled the body.
20
N
MIN.
ENVIRONMENTAL CHARACTERISTICS
1) Insulation resistance: 10 M MIN.
(At high humidity)
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
95% for 96 hours.
X
-
2) Insulation resistance: 100 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
Rapid Change of Temperature Temperature: -55 → R/T(1) → +85 → R/T C
Time: 30 → 2 to 3 → 30 → 2 to 3 min
for 5 cycles.
1) Insulation resistance: 100 M MIN.
X
X
-
-
2) No damage, cracks or looseness of parts.
Subjected to 5% salt spray for 48 hours.
Corrosion Salt Mist
No heavy corrosion which impairs functionality.
(compatibility)
Dry Heat
Subjected to +85℃ for 96 hours.
No damage, cracks or looseness of parts.
X
X
X
-
-
-
Cold
Subjected to -55℃ for 96 hours.
No damage, cracks or looseness of parts.
No water penetration into the connector.
Sealing(2)
Air Tightness(2)
Subjected to a depth of 1.8 m for 48 hours.
17.6 kPa of air pressure applied to the inside of the mated
connector for 30 seconds.
No air bubbles emitted from the inside of the
connector.
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
NOTES
APPROVED
CHECKED
DESIGNED
EJ.KUNII
EJ.KUNII
20220301
20220301
20220228
(1) R/T:Room Temperature
(2) Sealing and Air Tightness are tested in mated condition with an
applicable connector.
TR.YAMANOUE
DRAWN
TR.YAMANOUE
20220228
Unless otherwise specified, refer to IEC 60512. (JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-384950-00-00
LF13WBRB-20SC
SPECIFICATION SHEET
0
1/1
HIROSE ELECTRIC CO., LTD.
CL0136-1033-0-00
△
FORM HD0011-2-1