APPLICABLE STANDARD
Operating
Storage Temperature
Range
-25C to +85C
-10C to +60C
Temperature Range
26 to 30 AWG
Insulation outside diameterφ1 MAX
AC 30 V, DC 42 V
2A
Wire Size
Rating
Voltage
Current
Applicable Cable
-
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
-
-
Contact Resistance
Insulation Resistance
Measured at DC 1A.
30 m MAX.
Measured at 100 V DC.
1000 M MIN.
Voltage Proof
300 V AC applied for 1 min.
No breakdown.
X
-
MECHANICAL CHARACTERISTICS
Contact Insertion and
Extraction Forces
Measured with a
-
steel gauge.
Insertion and extraction forces:
-
N MIN.
X
X
-
-
Connector Insertion and
Withdrawal Forces
Measured with an applicable connector.
(Without lock)
Insertion and withdrawal forces : 50 N MAX.
Mechanical Operation
Mated and unmated 1000 times.
Contact resistance: 50 m MAX.
X
X
-
-
Vibration
Frequency: 10 Hz to 55 to 10 Hz every cycle (5 min per
1) No electrical discontinuity of more than 10 s.
cycle)
2) No damage, cracks or looseness of parts.
Single amplitude: 0.75 mm
Performed over 10 cycles in each of three mutually
perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
1) No electrical discontinuity of more than 10 s.
Performed 3 times in each of three mutually perpendicular
directions.
2) No damage, cracks or looseness of parts.
X
-
Breaking Strength
Force is applied to the plug body in up, down,
left and right directions while mated.
No breakage at 100 N.
X
X
-
-
Contact Retention Force
Applying a pull force the wire after the applicable
crimped contact is assembled the body.
20
N
MIN.
ENVIRONMENTAL CHARACTERISTICS
1) Insulation resistance: 10 M MIN.
(At high humidity)
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
95% for 96 hours.
X
-
2) Insulation resistance: 100 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
Rapid Change of Temperature Temperature: -55 → R/T(1) → +85 → R/T C
Time: 30 → 2 to 3 → 30 → 2 to 3 min
for 5 cycles.
1) Insulation resistance: 100 M MIN.
X
X
-
-
2) No damage, cracks or looseness of parts.
Subjected to 5% salt spray for 48 hours.
Corrosion Salt Mist
No heavy corrosion which impairs functionality.
(compatibility)
Dry Heat
Subjected to +85℃ for 96 hours.
No damage, cracks or looseness of parts.
X
X
X
-
-
-
Cold
Subjected to -55℃ for 96 hours.
No damage, cracks or looseness of parts.
No water penetration into the connector.
Sealing(2)
Subjected to a depth of 1.8 m for 48 hours.
Air Tightness(2)
17.6 kPa of air pressure applied to the inside of the mated
connector for 30 seconds.
No air bubbles emitted from the inside of the
connector.
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
NOTES
APPROVED
CHECKED
DESIGNED
EJ.KUNII
EJ.KUNII
20220301
20220301
20220228
(1) R/T:Room Temperature
(2) Sealing and Air Tightness are tested in mated condition with an
applicable connector.
TR.YAMANOUE
DRAWN
TR.YAMANOUE
20220228
Unless otherwise specified, refer to IEC 60512. (JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-383069-00-00
LF13WBRB-20PC
SPECIFICATION SHEET
0
1/1
HIROSE ELECTRIC CO., LTD.
CL0136-1124-0-00
△
FORM HD0011-2-1