APPLICABLE STANDARD
OPERATING
-25 C TO +85
AC 30 V , DC 42
C
STORAGE
-10
C TO +60
C
RATING
TEMPERATURE RANGE
TEMPERATURE
RANGE
VOLTAGE
CURRENT
V
WIRE SIZE
MAX AWG#26
2
A
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
X
X
X
X
X
X
CONTACT RESISTANCE
INSULATION RESISTANCE
VOLTAGE PROOF
CONTACT SHALL BE MEASURED AT DC
1
A
15
m
MAX.
MIN.
100 V DC.
1000
M
300 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES :
INSERTION AND WITHDRAWAL FORCES
N MIN.
-
-
-
WITHDRAWAL FORCES
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR
WITHOUT LOCKING DEVICE.
X
LOCKING DEVICE WITH UNLOCK
LOCKING DEVICE WITH LOCK
:
50 N MAX.
- N MAX.
:
X
X
-
-
MECHANICAL OPERATION
VIBRATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
CONTACT RESISTANCE: 30
m
MAX.
FREQUENCY: 10 → 55 → 10 (Hz) (1CYC,5min),
①NO ELECTRICAL DISCONTINUITY OF 10 s.
SINGLE AMPLITUDE 0.75 mm, AT 10 CYC,FOR 3 DIRECTIONS.
IN OPPOSITE DIRECTIONS OF EACH 3 DEMENSION AXIS FOR 3
TIMES AT 490 m/s2 DURATIONS OF PULSE 11 ms.
②NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
SHOCK
X
X
-
-
BREAKING STRENGTH
MAX 100 N SHALL BE APPLIED TO CABLE IN UP AND DOWN,LEFT
AND RIGHT DIRECTIONS WHEN MATED.
NO BREAKAGE MAX 100N.
ENVIRONMENTAL CHARACTERISTICS
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
X
-
(STEADY STATE)
② INSULATION RESISTANCE: 100 MΩ MIN
(AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
CORROSION SALT MIST
DRY HEAT
TEMPERATURE -55→ R/T(1) → +85 → R/T ℃
① INSULATION RESISTANCE: 100 MΩ MIN..
② NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
NO HEAVY CORROSION RUIN THE FUNCTION.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DEFORMATION OF CASE OF EXCESSIVE LOOSENESS
OF THE TERMINALS.
X
-
TIME 30 → 2 TO 3 → 30 → 2 TO 3 min UNDER 5 CYCLES.
X
X
X
-
-
-
EXPOSED IN
5
SALT WATER SPRAY FOR 48 h.
EXPOSED AT + 85 ℃,96 h.
COLD
EXPOSED AT – 55 ℃,96 h.
RESISTANCE TO SOLDERING
HEAT
PLACE SOLDERING IRON(IRON TIP TEMPERATURE +350±10℃)
AND SOLDER TO SOLDERING POT AREA FOR 5±1 s.
PLACE SOLDERING IRON(IRON TIP TEMPERATURE +350±10℃)
AND SOLDER TO SOLDERING POT AREA FOR 2 TO 3 s.
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
X
-
SOLDERABILITY
A SOLDERING SIDE IS TO BE WET WITH SOLDER.
AND, NO SMALL LUMP OF THE SOLDER.
X
X
-
-
SEALING(2)
NO WATER PENETRATION INSIDE CONNECTOR.
AIR TIGHTNESS(2)
APPLY AIR PRESSURE 17.6kPa FOR 0.5min TO INSIDE CONNECTOR. NO AIR BUBBLES INSIDE CONNECTOR.
X
X
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
REMARK
APPROVED
CHECKED
DESIGNED
TP.KOMATSU
EJ.KUNII
20210720
20210720
20210720
NOTES(1)R/T : ROOM TEMPERATURE
(2)SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER MATED CONDITION WITH AN
APPLICABLE CONNECTOR.
HR.SATO
Unless otherwise specified, refer to IEC 60512(JIS C 5402).
DRAWN
TR.YAMANOUE
20210720
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-119465-00-00
LF13WBRB-20P
CL0136-1023-0-00
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1/1
0
△
FORM HD0011-2-1