APPLICABLE STANDARD
-25 C TO
+85 C
-10
C TO
+60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
WIRE SIZE
CURRENT
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
MECHANICAL CHARACTERISTICS
VIBRATION
FREQUENCY: 10 → 55 → 10 (Hz) (1CYC,5min),
SINGLE AMPLITUDE 0.75 mm, AT 10 CYC,FOR 3 DIRECTIONS.
NO SEPERATION FROM APPLICABLE CONNECTOR.
-
SHOCK
IN OPPOSITE DIRECTIONS OF EACH 3 DEMENSION AXIS FOR 3 NO SEPERATION FROM APPLICABLE CONNECTOR.
TIMES AT 490 m/s2 DURACTIONS OF PULSE 11 ms.
X
X
-
-
MECHANICAL OPERATION
100 TIMES INSERTIONS AND EXTRACTIONS.
PASS THE SEALING TEST.
ENVIRONMENTAL CHARACTERISTICS
RAPID CHANGE OF TEMPERATURE TEMPERATURE -55→ R/T(1) → +85 → R/T ℃
NO DAMAGE,CRACK OF PARTS.
X
-
TIME 30 → 2 TO 3 → 30 → 2 TO 3 min UNDER 5 CYCLES.
DRY HEAT
EXPOSED AT + 85 ℃,96 h.
NO DAMAGE,CRACK OF PARTS.
NO DAMAGE,CRACK OF PARTS.
X
X
X
X
-
-
-
-
COLD
EXPOSED AT - 55 ℃,96 h.
DAMP HEAT(STEADY STATE)
SEALING(2)
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
NO DAMAGE,CRACK OF PARTS.
NO WATER PENETRATION INSIDE CONNECTOR.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
APPROVED
CHECKED
DESIGNED
EJ.KUNII
EJ.KUNII
16.10.03
16.10.03
16.09.30
NOTES(1) R/T:ROOM TEMPERATURE
(2) SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER MATED CONDITION WITH
AN APPLICABLE CONNECTOR.
SJ.SHIMIZU
DRAWN
SY.KONDO
16.09.30
Unless otherwise specified, refer to IEC 60512(JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-119606-00-00
LF13WBR-C2
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL136-3011-0-00
FORM HD0011-2-1