APPLICABLE STANDARD
TÜV approved (R50079865). UL approved (E52653).
OPERATING
-25℃ TO +85℃
STORAGE
-10℃ TO +60℃
RATING
TEMPERATURE RANGE
VOLTAGE
TEMPERATURE RANGE
WIRE SIZE
MAX AWG#16
AC,DC 125 V (TÜV)
AC,DC 250 V (UL)
10 A
1
CURRENT
APPLICABLE CABLE
φ7.3±0.2
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
X
-
X
X
-
X
5
m MAX.
m MAX.
CONTACT RESISTANCE
CONTACT SHALL BE MEASURED AT DC
CONTACT SHALL BE MEASURED AT DC
500 V DC.
1
A
A
―
―
1000 M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
X
X
1250 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
―― BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES :
― N MIN.
-
-
-
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR
WITHOUT LOCKING DEVICE.
INSERTION AND WITHDRAWAL FORCES :
30 N MAX.
X
X
-
-
CONTACT RESISTANCE:
10 m MAX.
MECHANICAL OPERATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
-
―― RESISTANCE: ― m MAX.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
X
X
X
VIBRATION
FREQUENCY 10 → 55 → 10 (Hz) (1CYC, 5min),
―
―
―
SINGLE AMPLITUDE 0.75 mm, AT 10 CYC FOR 3 DIRECTIONS. ② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
NO BREAKAGE MAX 100 N.
SHOCK
IN OPPOSITE DIRECTIONS OF EATH 3 DIMENSION AXIS
FOR 3 TIMES AT 490 m/s2 DURACTIONS OF PULSE 11 ms.
MAX 100 N SHALL BE APPLIED TO CABLE IN UP AND DOWN,
LEFT AND RIGHT DIRECTIONS WHEN MATED.
BREAKING STRENGTH
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
X
X
-
-
(STEADY STATE)
② INSULATION RESISTANCE: 100 MΩ MIN (AT DRY).
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 100 MΩ MIN.
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55 → R/T(1) → +85 → R/T ℃
TIME 30 → 2 TO 3 → 30 → 2 TO 3 min
UNDER 5 CYCLES.
EXPOSED IN 5 SALT WATER SPRAY FOR 48 h.
CORROSION SALT MIST
DRY HEAT
NO HEAVY CORROSION RUIN THE FUNCTION.
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
X
X
X
X
-
-
-
-
EXPOSED AT +85 ℃ , 96 h.
EXPOSED AT –55 ℃ , 96 h.
COLD
RESISTANCE TO SOLDERING
HEAT
SOLDER TEMPERATURE, +350±10 ℃, FOR IMMERSION
DURATION, 5±1 s.
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
SOLDERABILITY
SOLDERED AT SOLDER TEMPERATURE, +350±10 ℃ FOR
IMMERSION DURATION, 2 TO 3 s.
SOLDER SURFACE TO BE FREE FROM PIN-HOLE.
NO WETTING AND OTHER DEFECTS.
-
X
SEALING
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
NO WATER PENETRATION INSIDE CONNECTOR.
X
X
-
-
AIR TIGHTNESS
APPLY AIR PRESSURE 17.6 kPa FOR 0.5 min TO INSIDE
CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
KN.IKEHARA
CHECKED
DATE
1
DIS-C-00003269
HN.TANAKA
20190614
1
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HY.KOBAYASHI
HY.KOBAYASHI
TY.SUZUKI
20180315
20180315
20180315
20180315
NOTE(1) R/T:ROOM TEMPERATURE
Unless otherwise specified, refer to IEC 60512. (JIS C 5402)
TY.SUZUKI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-114241-31-00
LF10WBP-4P(31)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1
1/1
CL136-0006-5-31
△
FORM HD0011-2-1