APPLICABLE STANDARD
Operating
-25C to +85C (95%RH MAX)
AC 30 V , DC 42
Storage Temperature
Range
-10C to +60 C (95%RH MAX)
RATING Temperature Range
Voltage
V
Wire size
MAX AWG#26
Current
2
A
Applicable Cable
φ7.3±0.2
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
General examination
Examined visually and with a measuring instrument.
Confirmed visually.
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
X
X
Contact resistance
Measured at
1
A MAX (DC or 1 000 Hz).
15 m MAX.
Insulation resistance
100 V DC.
1000 M MIN.
X
X
Voltage proof
300 V AC. For 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Insertion force
Extraction force
N MAX.
N MIN.
Contact Insertion and Extraction
Measured with a φ
steel gauge.
-
-
-
-
-
-
forces
-
X
Mating and Unmating Forces
Measured with an applicable connector.
Mated and unmated 1000 times.
Mating force 50 N MAX.
Unmating force 50 N MAX.
X
Mechanical Operation
Vibration
1) Contact resistance: 30 m MAX.
X
2) No damage, cracks or looseness of parts.
Frequency: 10 Hz to 55 Hz
1) No electrical discontinuity of more than10 s.
2) No damage, cracks or looseness of parts.
Single amplitude: 0.75 mm
Acceleration: 98 m/s2
X
X
-
Performed over 10 cycles in each of three mutually perpendicular
directions.
Acceleration: 490 m/s2
Shock
Half sine wave pulses of 11 ms.
Performed 3 times in each of three mutually perpendicular
directions.
-
Breaking Strength
Max 50 N shall be applied to cable in up and down, left and right No breakage .50N MAX
directions when mated.
X
X
-
-
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
Subjected to 40 ℃, 90 ~ 95 % for 96 h.
1) Insulation resistance: 10 MΩ MIN (At high humidity).
2) insulation resistance: 100 MΩ MIN (When dry).
3) No damage, crack or looseness of parts.
1) insulation resistance: 100 MΩ MIN.
(Steady State)
Rapid Change of Temperature
Temperature: -55→ R/T(1) → +85 → R/T ℃
Time: 30 → 2 to 3 → 30 → 2 to 3 min for 5 cycles.
Subjected to 5 salt water spray for 48 h.
X
-
2) No damage, cracks or looseness of parts.
No heavy corrosion which impairs functionality.
Corrosion Salt Mist
Dry Heat
X
X
X
X
-
-
-
-
Subjected to + 85 ℃ for 96 h.
Subjected to - 55 ℃ for 96 h.
No damage, cracks or looseness of parts.
No damage, cracks or looseness of parts.
Cold
Resistance to Soldering Heat
Solder temperature, +350±10℃, for immersion duration,
No deformation or case of excessive looseness of
terminals.
5±1 s.
Solderability
Soldered at solder temperature, +350±10℃ for immersion
duration, 2 to 3 s.
The solder shall have wetted the soldering surface and
there shall be no small lumps of solder.
X
-
Sealing(2)
Subjected at A depth of 1.8 m for 48 h.
No water penetration into the connector.
X
X
-
-
Air tightness(2)
17.6 kPa of air pressure applied to the inside of the mated
connector for 30s.
No air bubbles emitted from the inside of the
Connector.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
NOTES
APPROVED
CHECKED
DESIGNED
DRAWN
HY.KOBAYASHI
HY.KOBAYASHI
TY.SUZUKI
18.02.22
18.02.22
18.02.21
18.02.19
(1) R/T:Room Temperature
(2) Sealing and airtightness shall be tested under mated condition with an applicable connector.
Unless otherwise specified, refer to IEC 60512(JIS C 5402).
HM.SAITO
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-118147-31-00
DRAWING NO.
PART NO.
CODE NO.
LF10WBLP-12PA(31)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL136-0025-0-31