Current Transducer HNC- 050 .. 100P IPN = 50 .. 100 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
DC current
Primary current
measuring range
Type
IPN (A)
IP (A)
50
100
0 .. ± 75
0 .. ± 140
HNC - 050P
HNC - 100P
HNC - 050P HNC - 100P
RM
ISN
KN
Measuing resistance
Second nominal current
Turns ratio
60 .. 90
50
1 : 1000
60 .. 80
50
1 : 2000
W
mA
Features
· Hall effect measuring principle
· Galvanic isolation between primary
and secondary circuit
· Isolation voltage 2500 V
· Low power consumption
VC
IC
Vd
Supply voltage (± 5 %)
Current consumpution
R.m.s. voltage for AC isolation test, 50/60Hz, 1 min
± 15
15 + ISN
V
mA
kV
2.5
Accuracy-Dynamic performance data
Advantages
X
e
IO
Accuracy @ TA = 25°C
Linearity (0 .. ± IPN)
Electrical offset current @IP = 0, @TA = 25°C
Hysteresis offset current @ IP = 0,
after an excursion of IPN
± 1 % of IPN
· Easy mounting
< ± 0.5
± 0.2
%
mA
L
· Small size and space saving
· Only one design for wide current
ratings range
IHC
± 0.15
mA
· High immunity to external interference
IOT
t r
Thermal drift of IO
Response time @ 90% of IP
0°C .. +70°C
± 0.005 ms/°C
<1 µs
TCe
Thermal drift of the gain (% of reading)
< ± 0.004 %/°C
Applications
G
· DC motor drives
· Switched Mode Power Supplies
(SMPS)
General data
· AC variable speed drives
· Uninterruptible Power Supplies
(UPS)
TA
TS
Ambient operating temperature
Ambient storage temperature
- 10 .. + 80 °C
- 15 .. + 85 °C
HNC - 200P HNC - 300P
· Battery supplied applications
· Inverters
RS
m
Secondary coil Resistance
@TA = 25°C
75
95
W
Mass
30
g
010301/1
www.nanalem.co.jp