Current Transducer HNC-050P 50A-50mA IPN = 50 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
45361
Electrical data
Features
IPN
IPM
VC
IC
Primary nominal current rms
Primary current, measuring range
Supply voltage (± 5 %)
50
A
A
V
± 75
± 15
· Hall effect measuring principle
· Galvanic isolation between primary
and secondary circuit
Current consumption
15mA+(IPN/1000)mA
Vd
Rms voltage for AC isolation test, 50Hz, 1min
Isolation resistance @ 500 VDC
Output current @ ± IPN, RL = 80 W, TA = 25°C
Load resistance
2.5
kV
MW
mA
W
· Low power consumption
· Insulated plastic case recognized
according to UL 94-V0
RIS
IOUT
RL
> 500
50
80
Advantages
Accuracy-Dynamic performance data
· Easy installation.
X
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error 1) (0 .. ± IPN)
< ± 1
%
· Small size and space saving
· Only one design for wide current
ratings range
· High immunity to external
interference
e
< ± 0.5 % of IPN
L
IOE
IOH
Electrical offset current @ TA = 25°C, IP = 0
Hysteresis offset current @ IP = 0;
after an excursion of 1 x IPN
< ± 0.2
mA
< ± 0.15
mA
TCIOE
Temperature coefficient of IOE @ TA = - 5 .. + 70 °C < ± 0.005 mA/K
Temperature coefficient of IOUT (% of reading)
TCIOUT
@ TA = -5..+70°C
< ± 0.04
< 1
%/K
µs
Applications
tr
Response time to 90% of IPN step
· DC motor drives
· Switched Mode Power Supplies
(SMPS)
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 80
- 15 .. + 85
20
°C
°C
g
· AC variable speed drives
· Uninterruptible Power Supplies
(UPS)
· Battery supplied applications
· Power supplies for welding
applications
Applicationdomain
· Industrial
Note : 1) Linearity data exclude the electrical offset.
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061025/1