5秒后页面跳转
HAS50-P_06 PDF预览

HAS50-P_06

更新时间: 2022-04-23 23:00:11
品牌 Logo 应用领域
莱姆 - LEM 传感器
页数 文件大小 规格书
2页 791K
描述
Current Transducers

HAS50-P_06 数据手册

 浏览型号HAS50-P_06的Datasheet PDF文件第2页 
IPN = 50..600 A  
Current Transducers HAS 50..600-P  
For the electronic measurement of currents: DC, AC, pulsed, mixed,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
VOUT = ± 4 V  
Electrical data  
Primarynominal  
current rms  
IPN (A)  
Primary current,  
measuring range  
IPM (A)  
Type  
RoHS since  
date code  
50  
± 150  
± 300  
± 600  
± 900  
± 900  
± 900  
± 900  
HAS 50-P  
46065  
46062  
planned  
planned  
46131  
100  
200  
300  
400  
500  
600  
HAS 100-P  
HAS 200-P  
HAS 300-P  
HAS 400-P  
HAS 500-P  
HAS 600-P  
Features  
· Hall effect measuring principle  
· Galvanic isolation between primary  
and secondary circuit  
46216  
planned  
VC  
IC  
ÎP  
Vd  
Vb  
RIS  
VOUT  
ROUT  
RL  
Supply voltage (± 5 %)  
Current consumption  
Overload capability  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Rated isolation voltage rms, safe separation  
Isolation resistance @ 500 VDC  
± 15  
± 15  
30,000  
3
5001)  
> 1000  
V
mA  
At  
kV  
V
· Isolation voltage 3000 V~  
· Low power consumption  
· Extended measuring range (3 x IPN)  
· Insulated plastic case made of  
polycarbonate PBT recognized  
according to UL 94-V0  
MW  
Output voltage (Analog)@ ± IPN, RL = 10 kW, TA = 25°C ± 4 V ± 40 mV  
· Right angle pins for direct PCB  
mounting  
Output internal resistance  
approx. 100  
> 1  
W
kW  
6)  
Load resistance  
Advantages  
Accuracy - Dynamic performance data  
· Easy mounting  
X
Accuracy @ IPN, TA = 25°C (excluding offset)  
Linearity error 2) (0 .. ± IPN)  
Electrical offset voltage, TA = 25°C  
Hysteresis offset voltage @ IP = 0,  
after an excursion of 1 x IPN  
< ± 1  
< ± 1 % of IPN  
< ± 20  
%
· Small size and space saving  
· Only one design for wide current  
ratings range  
· High immunity to external  
interference.  
e
L
VOE  
VOH  
mV  
< ± 20  
< ± 2  
< ± 1  
< ± 0.1  
< 3  
mV  
mV/K  
mV/K  
%/K  
ms  
TCVOE  
Temperature coefficient of VOE HAS 50-P  
HAS 100..600-P  
Temperature coefficient of VOUT (% of reading)  
Response time to 90% of IPN step  
TCVOUT  
tr  
Applications  
di/dt  
BW  
di/dt accurately followed  
> 50  
DC .. 50  
A/ms  
kHz  
· AC variable speed drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
· Switched Mode Power Supplies  
(SMPS)  
· Power supplies for welding  
applications.  
Frequency bandwidth (small signal, -3dB) 3) 4)  
General data  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
- 10 .. + 80 °C  
- 25 .. + 85 °C  
approx. 80 g  
Mass  
Standards  
5)  
EN 50082-2  
1)  
Notes : Pollution class 2, overvoltage category III.  
2)  
Linearity data exclude the electrical offset.  
Please refer to derating curves in the technical file to avoid excessive  
core heating at high frequency.  
Amorphous core option for high frequency application.  
Please consult characterisation report for more technical details and  
application advice.  
3)  
ApplicationDomain  
· Industrial  
4)  
5)  
6)  
If the customer uses 1kW of the load resistor, the primary current has to  
be limited as the nominal.  
Page 1/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
061019/3  
www.lem.com  

与HAS50-P_06相关器件

型号 品牌 描述 获取价格 数据表
HAS-50-R MSYSTEM Space-saving Plug-in Signal Conditioners H-UNIT

获取价格

HAS-50-R/Q MSYSTEM Space-saving Plug-in Signal Conditioners H-UNIT

获取价格

HAS50S HITRON CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS SINGLE OU

获取价格

HAS50-S LEM Current Transducers HAS 50 to 600-S

获取价格

HAS50-S_06 LEM Current Transducer

获取价格

HAS50-S033075 HITRON CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS SINGLE OU

获取价格