Current Transducer FA-050..100PV
IPN DC = 50 .. 100 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Features
Primary continuous
direct current (nominal)
IPN DC (A)
Primary current,
measuring range
IPM (A)
Type
RoHS since
date code
· Closed loop (compensation) current
transducer using the Hall effect
· Galvanic isolation between primary
and secondary circuit
· Isolation voltage 2500 V~
· Compact design for PCB mounting
· Low power consumption
50
100
0 .. ± 70
0 .. ± 130
FA-050PV 50A-4V
FA-100PV 100A-4V
planned
46209
VOUT
IC
Output voltage (Analog) @ ± IPN DC, RL = 10kW, TA = 25°C ± 4
V
Current consumption FA-050PV
FA-100PV
16 mA ± IPN DC/ 1000A
16 mA ± IPN DC/ 2000A
VC
Vd
Supply voltage (± 5 %)
± 15
2.5
V
Rms voltage for AC isolation test, 50 Hz, 1min
kV
Advantages
Accuracy-Dynamic performance data
· Easy mounting
· Small size and space saving
· Only one design for wide current
ratings range
· High immunity to external
interference.
X
Accuracy @ TA = 25°C, + 15 V (+ 5 %)
< ± 1.5% of IPN DC
< ± 0.25% of IPN DC
e
Linearity error (0 .. ± IPN DC)
L
VOE
VOH
Electrical offset voltage @ IP = 0, @ TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN DC
< ± 0.016
V
< ± 0.012
< ± 0.4
< ± 0.04
< 1
V
mV/K
%/K
µs
TCVOE
TCVOUT
tr
Temperature coefficient of VOE
Temperature coefficient of VOUT (% of reading)
Response time to 90% of IPN DC step
Applications
· Static converters for DC motor drives
· Switched Mode Power Supplies
(SMPS)
· AC variable speed drives and servo
motor drives
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 70
- 15 .. + 80
25
°C
°C
g
· Uninterruptible Power Supplies
(UPS)
· Battery supplied applications
· Power supplies for welding
applications
Applicationdomain
· Industrial
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061030/2
www.lem.com