5秒后页面跳转
CV3-1500 PDF预览

CV3-1500

更新时间: 2022-04-23 23:00:11
品牌 Logo 应用领域
莱姆 - LEM /
页数 文件大小 规格书
2页 86K
描述
Voltage Transducer

CV3-1500 数据手册

 浏览型号CV3-1500的Datasheet PDF文件第2页 
Voltage Transducer CV 3-1500  
VPN = 1000 V  
For the electronic measurement of voltages : DC, AC, pulsed...,  
with a galvanic isolation between the primary circuit (high voltage)  
and the secondary circuit (electronic circuit).  
Electrical data  
VPN  
VP  
VS  
KN  
RL  
CL  
VC  
IC  
Primary nominal r.m.s. voltage  
Primary voltage, measuring range  
Secondary analog voltage @ VP max  
Conversion ratio  
Load resistance  
Capacitive loading  
Supply voltage (± 5 %)  
Current consumption  
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn  
R.m.s. voltage for partial discharge extinction @ 10 pC 2  
1000  
0 .. ± 1500  
10  
1500 V/10 V  
³ 1  
£ 5  
± 15  
V
V
V
Features  
· Closed loop (compensated) voltage  
transducer  
· Insulated plastic case recognized  
according to UL 94-V0  
kW  
nF  
V
mA  
kV  
kV  
· Patent pending.  
32 + VS /RL  
6
Vd  
Ve  
Advantages  
· Excellent accuracy  
· Very good linearity  
· Low thermal drift  
Accuracy - Dynamic performance data  
· Low response time  
· High bandwidth  
· High immunity to external  
interference  
Typ Max  
± 0.2  
XG  
VO  
Overall accuracy @ VP max  
Offset voltage @ VP = 0  
TA = 25°C  
- 40°C .. + 85°C  
TA = 25°C  
%
%
± 0.6  
± 5.0 mV  
± 13.0 mV  
· Low disturbance in common mode.  
- 40°C .. + 85°C  
tr  
Response time 1) @ 90 % of VP max  
0.4  
900  
µs  
V/µs  
Applications  
dv/dt dv/dt accurately followed  
f
Frequency bandwidth (- 1 dB) @ 33 % of VPN  
DC .. 800  
kHz  
· AC variable speed drives and servo  
motor drives  
General data  
· Static converters for DC motor drives  
· Uninterruptible Power Supplies  
(UPS)  
· Power supplies for welding  
applications  
TA  
TS  
P
R1  
m
Ambient operating temperature  
Ambient storage temperature  
Total primary power loss  
Primary resistance  
- 40 .. + 85  
- 45 .. + 90  
2.8  
360  
560  
°C  
°C  
W
kW  
g
· Railway overhead line voltage  
measurement.  
Mass  
Standards  
2)  
EN 50155  
1)  
Notes : With a dv/dt of 900 V/µs  
2)  
A list of corresponding tests is available  
030129/7  
LEM Components  
www.lem.com  

与CV3-1500相关器件

型号 品牌 描述 获取价格 数据表
CV3-150-JBW RCD General Purpose Inductor, 15uH, 5%, 1 Element, ROHS COMPLIANT

获取价格

CV3-150-KBQ RCD General Purpose Inductor, 15uH, 10%, 1 Element,

获取价格

CV3-150-KBW RCD General Purpose Inductor, 15uH, 10%, 1 Element, ROHS COMPLIANT

获取价格

CV3-151-JB RCD General Purpose Inductor, 150uH, 5%, 1 Element,

获取价格

CV3-151-JBQ RCD General Purpose Inductor, 150uH, 5%, 1 Element,

获取价格

CV3-151-JBW RCD General Purpose Inductor, 150uH, 5%, 1 Element, ROHS COMPLIANT

获取价格