Voltage Transducer AV 100-2000
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
VPN = 2000 V
Electrical data
VPN
Primary nominal r.m.s. voltage
2000
V
V
VDC
W
Features
VPmax Primary voltage measuring range
± 30001)
4500 (1s/h)
17.8M
ˆ
Non-measurable overload
Primary input resistance
Measuring resistance
@ VC=11.4V
· Insulated plastic case recognized
according to UL 94-V0
· Included primary resistor.
VP
RP
RM
RM min
0
0
RM max
47
184
W
W
@ VC=22.8V
ISN
VC
IC
Secondary nominal r.m.s. current
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 min
Max Common mode voltage
and
50
mA
V
mA
kV
Advantages
DC± 12 .. 24
50+IS
6.5
· Low power
Vd
· Excellent accuracy
· Very good linearity
· Low thermal drift
UHT+ + UHT- £ 4.2 kVDC
½UHT+ - UHT-½£ VPMAX
Ve
R.m.s. voltage for partial discharge
extinction @ 10pC
· Low response time
· High bandwidth
2.2
kV
· High immunity to external
interference
Accuracy - Dynamic performance data
· Low disturbance in common mode.
XG
XG
XG
Overall Accuracy @ VPN , TA = + 25°C
Overall Accuracy @ VPN , TA = - 25 .. + 70°C
Overall Accuracy @ VPN , TA = - 40 .. + 85°C
Linearity @ TA = 25°C
Offset current @ VP = 0, TA = 25°C
Response time@ 10 % of VPN
Frequency bandwidth (- 3dB)
± 0.7
± 1.5
± 1.7
< 0.1
± 0.15
< 12
DC .. 13
%
%
%
%
mA
µs
Applications
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
e
L
IO
tr
f
kHz
· Power supplies for welding
applications.
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 40 .. + 85
- 50 .. + 90
375
°C
°C
g
Standards
EN 50155 (01.12.02)
EN 50124-1(01.03.01)
NFF16101/2(01.10.88)
Note : 1) Up to 2200 Vpk, 500 ms every 60 minutes & 2600 Vpk, 500 ms,12
times/year.
030805/2