描述
AC Current transducer

AP-B10_1 数据手册

 浏览型号AP-B10_1的Datasheet PDF文件第2页 
AC Current transducer AP-B10  
IPN = 10 .. 400 A  
Split core transducer for the electronic measurement AC waveforms  
current, with galvanic isolation between the primary (High power) and  
the secondary circuits (Electronic circuit). Switch selectable ranges  
and RMS 0-5V and 0-10V switch selectable voltage output.  
Electrical data  
Primary Nominal Current  
IPN (A.t.RMS)  
Analogue Output Signal  
VOUT (V)  
Type  
Features  
10,25,50  
0-5V or 0-10V  
0-5V or 0-10V  
0-5V or 0-10V  
0-5V or 0-10V  
AP 50 B10  
AP 100 B10  
AP 200 B10  
AP 400 B10  
· RMS output  
50,75,100  
100,150,200  
200,300,400  
· Split core type  
· 5V & 10V switch selectable voltage  
output  
RL  
VC  
IC  
Load resistance  
³ 10  
kW  
Supply voltage  
Current Consumption  
Limitation of voltage output (0-10V)  
Limitation of voltage output (0-5V)  
Overloaded input current  
+24 ±5% V DC  
· DIN mounting & Panel mounting  
· Eliminates insertion loss  
· Switch selectable ranges  
< 30  
14  
7
mA  
V
V
no limitation  
Accuracy-Dynamic performance data  
Advantages  
X
Accuracy @ IPN, TA = 25°C (without offset)  
Linearity (0 .. ± IPN)  
Electrical offset voltage, TA = 25°C  
Thermal drift of VOE  
Thermal drift of the gain (% of reading)  
Response time @ 90% of IP  
Frequency bandwidth (±1%)  
< ±1  
< ±0.5 % of IPN  
< ±0.5 % of IPN  
±1  
±0.1  
< 150  
% of IPN  
· Large aperture for cable up to  
Ø18mm  
e
VOLE  
VOT  
TCe  
tr  
· High isolation between primary and  
secondary circuits  
mV/K  
%/K  
m s  
G
· Easy to mount  
f
30 .. 2000 Hz  
General data  
Applications  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
Mass  
-20 .. +60  
-20 .. +85  
90  
IP20  
5.5  
5.5  
600  
V0  
°C  
°C  
g
· Automation systems  
Analog current reading for remote  
monitoring (e.g. motor) and  
software alarms.  
Protection type  
dCp  
dCl  
CTI  
Creepage distance  
Clearance distance  
Comparative tracking index (Group I)  
UL94 classification  
m m  
m m  
V
· Panelmeters  
Simple connection displays power  
consumption.  
Insulation category  
Vb  
Rated Voltage  
300  
V
with IEC 61010-1 standards and following conditions :  
- Single insulation  
- Over voltage category CAT III  
- Pollution degree PD2  
- None uniform field  
Vd  
Ve  
Vw  
R.m.s. voltage for AC insulation test, 50Hz, 1mn  
R.m.s. voltage for partial discharge extinction @ 10pC 1.5  
Peak impulse withstand voltage 1.2/50ms 6.1  
5
kV  
kV  
kV  
If insulated cable is used for the primary circuit, the voltage category  
could be improved with the following table :  
Cable insulation (primary)  
HAR 05  
Category  
600V CAT III  
1000V CAT III  
HAR 07  
041029/3  
Notes : Installation and maintenance should be done with power supply disconnected.  
The operator must have accrediation to install this material.  
The users must take care of all protection gurantee against electrical shock.  
.
LEM Components  
www.lem.com  

与AP-B10_1相关器件

型号 品牌 描述 获取价格 数据表
APB20N-700KG FUJIKURA Pressure Sensor,

获取价格

APB20R-025KG FUJIKURA Pressure Sensor,

获取价格

APB20R-200KG FUJIKURA Pressure Sensor,

获取价格

APB20R-700KG FUJIKURA Pressure Sensor,

获取价格

APB21N-050KV FUJIKURA Pressure Sensor,

获取价格

APB21N-500KG FUJIKURA Pressure Sensor,

获取价格