AC Current transducer AK-B-
IPN = 10..200A
A split Core transducer for the electronic measurement AC sinusoidal
waveforms current, with galvanic isolation between the primary (High
power)andthesecondarycircuits(Electroniccircuit).Jumperselectable
ranges and self powered transducers.
Electrical data
Features
Primary Nominal Current Analogue Output Signal1) Type
RoHS
· AC sinusoïdal measurement
· Average responding
· Split core box
IPN (A.t RMS)
10,20,50
VOUT (V DC)
Date Code
JULY 2006
5
AK 50 B5
AK 50 B10
AK 200 B5
10,20,50
10
5
· Self powered transducers
· Panel mounting
100,150,200
100,150,200
10
AK 200 B10 JULY 2006
· Voltage output
· Jumper selectable ranges
Vc
RL
Vb
Vd
f
Supply voltage
Load resistance
Self Powered
1
MW
V AC
kV AC
Hz
Advantages
Rated voltage(CAT III, PD2)
RMS Isolation voltage test, 50 Hz, 1mn
Frequency bandwith
150
3
· Large aperture
50-60
· High isolation between primary and
secondary circuits
· Easy to mount
Accuracy - Dynamic performance data
X
tr
Accuracy @ IPN, TA=25°C
± 1
%
Applications
Response time @ 90% of IPN
< 100
mS
· Automation systems
Analog current reading for remote
monitoring (e.g. motor).
General data
· Data loggers
TA
TS
m
Ambient operating temperature (0-95% RH)
Ambient storage temperature
-20..+50
-20..+85
°C
°C
g
Self-powered transducer does not
drain data logger batteries.
· Panel meters
Mass
120
Simple connection displays power
consumption.
Protection type
Safety
EMC
IP20
IEC 61010-1
EN 61326
Note: 1) For 0-5 V output model, no saturation output up to 8.2 V
and for 0-10 V output model, no saturation output up to 15 V
Options on request
· DIN mounting
060816/6
page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
www.lem.com