Series
LDC-185
Compact, LED, 200W
Constant Current
AC/DC Power Supply
Electrical Specifications
Key Features:
• 200W Output Power
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
305
431
63
Units
VAC
VDC
Hz
• UL 8750 Approved
Input Voltage Range
• Constant Current Output
• Active PFC
Input Frequency
Inrush Current, See Note 1
230 VAC
115 VAC
230 VAC
264 VAC
75
A Pk
2.10
0.90
0.80
• 90 - 305 VAC Input
Input Current
A
• IP65 / IP67 Rated
• Meets EN 55015, EN 61547
• Dimming Function
0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
Power Factor Correction
• >50 kHour Life Expectancy
• Lightning Surge Protection
• Over Volt/Temp Protection
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
See Note 2
10
%
S
115 VAC
230 VAC
277 VAC
1.5
0.5
Leakage Current
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
75
mA
Conditions
Min.
Typ.
5.0
1.0
Max.
Units
%
%
VIN = Min to Max
See Note 4
2.0
V P-P
Outputs Below 50 VDC
Outputs Above 71 VDC
5.0
10.0
Output Ripple Current
%
Hold-Up Time
115 VAC 12.0
10%, Autorecovery
mS
°C
Over Temperature Protection
Short Circuit Protection
Overload Protection
General
85
Continuous (Autorecovery)
Autorecovery
95
107
%IOUT
Units
VAC
Parameter
Conditions
Min.
Typ.
Max.
Input to Output 3,750
Isolation Voltage, 60S
Insulation Resistance
Input to FG 2,000
Output to FG
500
Input to Output
Input to FG 100 Mꢀ / 500 VDC / 25°C / 70% RH
Output to FG
EMI Characteristics
Parameter
Standard
EMI
EMS
Surge
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Conditions
Min.
-40
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing 95
Humidity
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com Weight
Physical
Case Size
See Mechanical Diagrams (Page 4)
33.1 Oz (950g)
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
220
50
Typ.
Max.
Units
kHours
kHours
MTBF
Life Expectancy
Safety Standards
Vibration
See Note 5
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
www.micropowerdirect.com