5秒后页面跳转
LCS-71-C/E PDF预览

LCS-71-C/E

更新时间: 2022-05-14 21:54:31
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 118K
描述
Plug-in Signal Conditioners M-UNIT

LCS-71-C/E 数据手册

 浏览型号LCS-71-C/E的Datasheet PDF文件第2页浏览型号LCS-71-C/E的Datasheet PDF文件第3页 
MODEL: LCS  
6: 10 mV/V  
7: 20 mV/V  
Plug-in Signal Conditioners M-UNIT  
0: Specify (strain gauge and excitation)  
STRAIN GAUGE TRANSMITTER  
(isolated)  
[2] OUTPUT  
Functions & Features  
Current  
• Providing a DC output signal proportional to a bridge type  
strain gauge utilized in load cells, pressure transducers  
• Supplying required excitation voltage  
• Drives bridges 80 Ω or above  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Excitation adjustable from 2 V to 10 V  
• Wide-range adjustment: 0 – 80 % for zero, 20 – 100 % for  
span  
• Fast response type available  
• LCD meter (engineering unit display selectable)  
• Simple loop test output (0 % and 100 %)  
• High-density mounting  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Typical Applications  
• Weighing system for tanks, hoppers, silos  
• Weighing system using cranes  
• Float level meter utilizing strain gauges  
50  
(1.97)  
80  
(3.15)  
[3] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
136  
(5.35)  
D: 115 V AC  
mm (inch)  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
MODEL: LCS–[1][2]–[3][4]  
J: 240 V AC  
DC Power  
ORDERING INFORMATION  
• Code number: LCS-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. LCS-2A-B/E2/Q)  
R: 24V DC (Not selectable with option /E or /E2)  
[4] OPTIONS (multiple selections)  
Input Signal Indicator  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
blank: Without  
/E: With (0.0 - 100.0 % display)  
/E2: With (in engineering unit with backlight and the  
simple loop test output)  
[1] INPUT STRAIN GAUGE  
1: 1 mV/V  
Response Time (0 – 90 %)  
blank: Standard (≤ 0.5 sec.)  
12: 1.25 mV/V  
15: 1.5 mV/V  
2: 2 mV/V  
/K: Fast response (Approx. 25 msec.)  
(Not selectable with Option /E2)  
Other Options  
3: 3 mV/V  
blank: none  
4: 4 mV/V  
/Q: Option other than the above (specify the specification)  
5: 5 mV/V  
LCS SPECIFICATIONS  
ES-1360 Rev.3 Page 1/3  
http://www.m-system.co.jp/  

与LCS-71-C/E相关器件

型号 品牌 描述 获取价格 数据表
LCS-71-C/E2 MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

LCS-71-C/K MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

LCS-71-C/Q MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

LCS-71-D MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

LCS-71-D/E MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

LCS-71-D/E2 MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格