Pre-Engineered Solution Datasheet
LCP FUSED COORDINATION PANEL
Selective Coordination Panel
Features/Benefits
ꢁꢀ
Meets NEC* requirements
Class CC and J fuse holders have built-in
ꢁꢀ
open-circuit indication
Fast-acting UL Listed fuses protect against short circuits
Feed through/sub feed lugs and 84-circuit
ꢁꢀ
ꢁꢀ
configuration available
Ground and neutral bars
Copper bus standard
ꢁꢀ
ꢁꢀ
Advanced Design Options
ꢁꢀ
MLO, Main Circuit Breaker, or Main Fused Pullout device
Fused Class T branch circuit pullout
Spare fuse cabinet accessory (holds six spare fuses)
SPD overvoltage protection
Any NEMA enclosure required
High amperage sub-fed branch breakers (J60A)
ꢁꢀ
Description
ꢁꢀ
The Littelfuse Coordination Panel provides a simple,
time-saving solution for circuits that require selective
coordination. This UL Listed product saves time and money,
and increases safety by minimizing system downtime.
ꢁꢀ
ꢁꢀ
ꢁꢀ
Specifications
Voltage Ratings
Main Bus Rating
Conductor Terminals 6 AWG - 300 kcmil
UL Listed
SCCR
Applications
120/208, 277/480 V ac
100 A - 400 A Standard
ꢁꢀ
Elevators
Hospitals
Hotel and Entertainment Industry
ꢁꢀ
ꢁꢀ
UL 67 Panel boards and UL 50 Enclosures
100 kA Max*
ꢁꢀ
Amusement Parks and Stadiums
* The following current-limiting fuses must be used directly upstream for 100kA SCCR.
1. 120/208 Volt Panels – LLNRK 100 A max, JTD_ID 200 A max, or JLLN 200 A max
2. 277/480 Volt Panels – LLSRK_ID 200 A max, JTD_ID 200 A max, or JLLS 200 A max
Code Requirements
Systems required by the NEC® to be selectively
coordinated include:
ꢁꢀ
Web Resources
For more information, visit: Littelfuse.com/lcp
Health Care Essential Electrical Systems (NEC 517.26)
ꢁꢀ
Elevators (NEC 620.62)
ꢁꢀ
Emergency Systems (NEC 700.32 in 2017)
*NEC is a trademark of its respective owner.
(NEC 700.28 in 2014)
ꢁꢀ
Legally Required Standby Systems (NEC 701.18)
ꢁꢀ
Critical Operations Power Systems (NEC 708.54)
Customizable Options (select one from each column)
BRANCH CIRCUIT
PROTECTION
DEVICES
STANDARD
ENCLOSURE
RATING
NUMBER
NEUTRAL
RATING MOUNTING
PANEL
PANEL
DOOR
FUSE
HOLDERS
PANEL
FEED
OF
VOLTAGE
MAIN DEVICES
OPTIONAL LUGS
CIRCUITS
†
(1-3 POLE)
2 - 42 120/208 V 3P, 4 W Up to 400 A MLO 100%
Surface
Flush
Standard 30 A Class CC 10 A- 60 A fused
circuit breaker
Top
None
NEMA 1
NEMA 3R
NEMA 4X
277/480 V 3P, 4 W
200%
Door-in-door 60 A Class J
Bottom
Sub-Fed
(MLO panels)
Up to 400 A MCB
or Main Fuse
Pullout
70 A-200 A
fused pullouts
≥ 70A Class T
Feed-Through
†
Fuses quoted separately to meet panel specifications. Coordination for breakers >60 A depends on upstream and
downstream devices. More specialized configurations are also available. Contact factory for more information.
Note: The Littelfuse LPS and LCP products are custom
designed products that fall outside standard specifications.
Littelfuse.com/lcp
© 2020 Littelfuse, Inc.
Rev: 061820