Code Conductor, Two-Hole, Standard Barrel with Window Lug
For Use with Stranded Copper Conductors
B1.
Cable Ties
Type LCD
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
• UL Listed and CSA Certified for wide wire range-taking capability
when crimped with Panduit® Uni-Die™ Dieless Crimping Tools‡
• Tested by Telcordia – meets NEBS Level 3
• American Bureau of Shipping approved
B2.
Cable
Accessories
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated
to 90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Available with NEMA hole sizes and spacing
B3.
Stainless
Steel Ties
W
C1.
Wiring
Duct
HOLE
SPACING
L
C2.
Surface
Raceway
B
INSPECTION
WINDOW
T
C3.
Abrasion
Protection
Figure Dimensions
(In.)
Copper
Conductor
Size
Stud Hole Stud Hole
Panduit
Color
Code
Panduit
Burndy
T&B
Wire Strip Std.
Size
(In.)
Spacing
(In.)
Die Index Die Index Die Index
Length
(In.)
Pkg.
Qty.
Part Number
W
B
T
L
No.‡
No.‡
No.‡
LCD10-10A-L*
#10
1/4
1/4
1/4
3/8
#10
1/4
1/4
1/4
3/8
#10
#10
#10
1/4
1/4
1/4
5/16
3/8
#10
#10
1/4
1/4
1/4
3/8
1/4
1/4
1/4
5/16
3/8
1/2
0.63
0.63
0.75
1.00
1.00
0.63
0.63
0.75
1.00
1.00
0.63
0.75
1.00
0.63
0.75
1.00
1.00
1.00
0.63
0.75
0.63
0.75
1.00
1.00
0.63
0.75
1.00
0.75
1.00
1.75
0.38 0.38 0.06 1.69
0.42 0.38 0.05 1.78
0.42 0.38 0.05 1.91
0.42 0.38 0.05 2.16
0.56 0.38 0.04 2.38
0.41 0.56 0.08 1.88
0.48 0.56 0.07 1.97
0.48 0.56 0.07 2.09
0.48 0.56 0.07 2.34
0.60 0.56 0.05 2.56
0.46 0.81 0.08 2.15
0.46 0.81 0.08 2.27
0.46 0.81 0.08 2.52
0.48 0.81 0.08 2.24
0.48 0.81 0.08 2.36
0.48 0.81 0.08 2.61
0.56 0.81 0.07 2.73
0.62 0.81 0.06 2.83
0.55 0.81 0.09 2.17
0.55 0.81 0.09 2.29
0.55 0.81 0.09 2.26
0.55 0.81 0.09 2.38
0.55 0.81 0.09 2.63
0.62 0.81 0.08 2.85
0.60 0.88 0.10 2.40
0.60 0.88 0.10 2.52
0.60 0.88 0.10 2.77
0.66 0.88 0.10 2.65
0.66 0.88 0.10 3.00
0.75 0.88 0.08 4.14
—
—
—
—
7/16
7/16
7/16
7/16
7/16
5/8
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
25
25
25
25
25
25
C4.
Cable
Management
LCD10-14A-L*
LCD10-14B-L*
LCD10-14D-L*
LCD10-38D-L*
LCD8-10A-L
LCD8-14A-L
LCD8-14B-L
LCD8-14D-L
LCD8-38D-L
—
—
—
—
—
—
49
49
49
49
49
7
—
—
—
—
21
21
21
21
21
24
24
24
24
24
24
24
24
29
29
29
29
29
29
33
33
33
33
33
33
#14 – #10
AWG STR,
#12 – #10
AWG SOL
—
—
—
—
—
—
D1.
Terminals
Red
P21
P21
P21
P21
P21
P24
P24
P24
P24
P24
P24
P24
P24
P29
P29
P29
P29
P29
P29
P33
P33
P33
P33
P33
P33
Red
5/8
Red
5/8
#8 AWG
D2.
Power
Connectors
Red
5/8
Red
5/8
LCD6-10A-L
LCD6-10B-L
LCD6-10D-L
LCD6-14A-L
LCD6-14B-L
LCD6-14D-L
LCD6-56D-L
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Gray
Gray
Gray
Gray
Gray
Gray
Brown
Brown
Brown
Brown
Brown
Brown
7/8
7
7/8
D3.
Grounding
Connectors
7
7/8
7
7/8
#6 AWG
7
7/8
E1.
Labeling
Systems
7
7/8
7
7/8
LCD6-38D-L
LCD4-10A-L
7
7/8
8
7/8
E2.
Labels
LCD4-10B-L
8
7/8
#4 – #3
AWG STR,
#2 AWG
SOL
LCD4-14A-L
LCD4-14B-L
LCD4-14D-L
LCD4-38D-L
LCD2-14A-Q
LCD2-14B-Q
LCD2-14D-Q
LCD2-56B-Q
LCD2-38D-Q
LCD2-12-Q
8
7/8
8
7/8
E3.
Pre-Printed
& Write-On
Markers
8
7/8
8
7/8
10
10
10
10
10
10
15/16
15/16
15/16
15/16
15/16
15/16
E4.
Permanent
Identification
#2 AWG
E5.
Lockout/
Tagout
& Safety
Solutions
‡See pages D3.58 – D3.61 for tool and die information.
*Not tested to NEBS Level 3 requirements.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
F.