Current Transducer LAH 50-P
IPN = 50 A
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
50
0 .. 110
TA = 70°C
RM min RMmax RM min RMmax
A
A
Features
1)
TA = 85°C
· Closed loop (compensated) current
transducer using the Hall effect
· Printed circuit board mounting
· Insulated plastic case recognized
according to UL 94-V0.
with ± 12 V
with ± 15 V
@ IPN [± A DC
@ IPN [A RMS
@ IPN [± A DC
]
0
0
0
0
221
115
335
195
0
0
0
0
214
108
327
188
W
W
W
W
2)
]
]
2)
@ IPN [A RMS
]
Advantages
ISN
KN
VC
IC
Vd
Ve
Vw
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
R.m.s. voltage for partial discharge extinction @ 10 pC > 2
25
1 : 2000
± 12 .. 15
10 (@ ± 15V) + IS mA
mA
· Excellent accuracy
· Very good linearity
V
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
5
kV
kV
kV
Impulse withstand voltage 1.2/50 µs
> 12
Accuracy - Dynamic performance data
X
Accuracy3) @ IPN, TA = 25°C
Linearity
± 0.25
< 0.15
%
%
· Current overload capability.
e
L
Typ Max
Applications
IO
Offset current @ TA = 25°C
± 0.15 mA
IOM
IOT
Residual current@ IP = 0, after an overload of 5 x IPN ± 0.10 ± 0.15 mA
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications.
Thermal drift of IO
0°C .. + 70°C
- 25°C .. + 85°C
± 0.10 ± 0.30 mA
± 0.10 ± 0.40 mA
tr a
tr
Reaction time @ 10 % of IPN
Response time 4) @ 90 % of IPN
< 200
< 500
ns
ns
di/dt di/dt accurately followed
f
> 200
DC .. 200
A/µs
kHz
Frequency bandwidth (- 1 dB)
General data
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance
- 25 .. + 85
- 40 .. + 90
135
142
°C
°C
W
@ TA = 70°C
@ TA = 85°C
W
Insulating material group
Mass
Standards
I
m
22
EN 50178
g
5)
1)
Notes : For 10 s, with RM £ 71 W (VC = ± 15 V)
2)
50 Hz Sinusoidal
Without IO & IOM
With a di/dt of 100 A/µs
A list of corresponding tests is available.
3)
4)
5)
010822/5
LEM Components