Current Transducer LAH 25-NP
IPN = 8-12-25 A
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
16038
Electrical data
Features
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
25
0 .. 55
TA = 70°C
RM min RMmax RM min RMmax
At
At
1)
· Closed loop (compensated) multi-
range current transducer using the
Hall effect
· Printed circuit board mounting
· Insulated plastic case recognized
according to UL 94-V0.
TA = 85°C
with ± 12 V
with ± 15 V
@ IPN [± At DC
@ IPN [At RMS
@ IPN [± At DC
]
0
0
257
155
0
0
252
150
W
W
W
W
2)
]
]
2)
67 371 70 366
67 236 70 231
@ IPN [At RMS
@ IP < IPN
]
3)
Advantages
ISN
KN
VC
IC
Vd
Vb
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
R.m.s. rated voltage 4)
25
mA
V
1 - 2 - 3 : 1000
± 12 .. 15
10 (@ ± 15V) + IS mA
5
600
· Excellentaccuracy
· Very good linearity
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
kV
V
Accuracy - Dynamic performance data
X
Accuracy 5) @ IPN, TA = 25°C
Linearity error
± 0.3
< 0.2
%
%
· Current overload capability.
e
L
Typ Max
Applications
IO
Offset current @ TA = 25°C
± 0.15 mA
IOM
IOT
Residual current @ IP = 0, after an overload of 5 x IPN ± 0.20 ± 0.25 mA
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
Thermal drift of IO
0°C .. + 70°C
- 25°C .. + 85°C
± 0.10 ± 0.60 mA
± 0.10 ± 0.70 mA
tr a
tr
Reaction time @ 10 % of IPN
Response time 6) @ 90 % of IPN
< 200
< 500
ns
ns
di/dt di/dt accurately followed
f
> 200
DC .. 200
A/µs
kHz
Frequency bandwidth (- 1 dB)
· Switched Mode Power Supplies
(SMPS)
General data
· Power supplies for welding
applications.
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance
- 25 .. + 85
- 40 .. + 90
99
104
20
°C
°C
W
W
g
@ TA = 70°C
@ TA = 85°C
m
Mass
Standards
EN 50178 : 1997
Notes : 1)During 10 s, with RM £ 109 W (VC = ± 15 V) - 2) 50 Hz Sinusoidal -
3) The measuring resistance RM min may be lower (see "LAH Technical Informa-
tion" leaflet) - 4) Pollution class 2, cat. III - 5) Without IO & IOM - 6) With a di/dt of
100 A/µs - 7)
060213/5
page1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
www.lem.com