COUNT
COUNT
DESCRIPTION OF REVISIONS
RE-6-2688
DATE
DESCRIPTION OF REVISIONS
CHKD DATE
BY CHKD
S.J.H L.S.M
BY
2022.05.11
1
1
APPLICABLE STANDARD
Operating
Temperature Range
Storage
-55℃ to 105℃ (Note1)
20% to 80% (Note2)
KW30-*P-*C(###)
-10℃ to 60℃ (Note3)
40% to 70% (Note3)
AWG#28 to 30
Temperature Range
Storage Humidity
Range
Voltage
RATING
Applicable
Connector
Applicable Cable
Current
AWG 30 : 1.0A
AWG 28 : 3.0A Insulation Diameter
1
φ0.8 ∼ φ0.88 mm
SPECIFICATIONS
ITEM
CONSTRUCTION
General Examination
Marking
TEST METHOD
REQUIREMENTS
QT AT
Visually and by measuring instrument.
Confirmed visually.
O
O
O
O
According to drawing.
ELECTRICAL CHARACTERISTICS
Contact Resistance
20mV MAX, 10mA (DC or 1000Hz).
30 mΩ MAX.
O
-
Millivolt Level Method
MECHANICAL CHARACTERISTICS
Mechanical Operation
Crimp Tensile Strength
Vibration
30 times insertion and extraction.
①Contact resistance : 50mΩ MAX
②No damage, crack or looseness of parts.
AWG#30 : 8N MIN
O
O
O
O
-
-
-
-
Pull out the cable after Crimp contact fixation.
AWG#28 : 16N MIN
Frequency 10 to 55 Hz, single amplitude 1.52 mm, ①No electrical discontinuity of 1μs.
at 2hours for 3 direction.
②Contact resistance : 50 mΩ MAX.
Acceleration 490 m/s2 duration of pulse 11 ms at
3times for 3 directions.
Shock
③No damage, crack or looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
Exposed at 40 ± 2 ℃ , humidity 90 to 95 %, 240 h.
①Contact resistance : 50 mΩ MAX.
②Insulation resistance : 100MΩ MIN.
③No damage, crack or looseness of parts.
①Contact resistance : 50 mΩ MAX.
②Insulation resistance : 100MΩ MIN.
③After Voltage proof test No flashover or
breakdown.
O
O
(Steady State)
-
-
Rapid Change of
Temperature
Temperatureꢀ-55 ℃ → 105 ℃
Time
30min → 30min
25 Cycles.
(The transferring time of the tank is 2 to 3 MIN)
(After leaving the room temperature for 1 to 2h.) ④No damage, crack or looseness of parts.
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before PCB on board. After PCB on board, operating temperature
and humidity range is applied for interim storage during transportation.
DRAWN
DESIGNED
CHECKED
APPROVED
Remark
RELEASED
S.W.CHOI
20.06.29
S.W.CHOI
20.06.29
S.M.LIM
20.06.30
S.M.LIM
20.06.30
Unless otherwise specified, refer to IEC 60512.
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST O: APPLICABLE TEST
PART NO.
HIROSE KOREA CO.,LTD.
SPECIFICATION SHEET
KW30-2830PCFA (800)
CL 6669-0002-6-800
F-1-021(Rev.0)
CODE NO.(OLD)
DRAWING NO.
CODE NO.
1
ELC4-632850
CL
2