APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
STORAGE
TEMPERATURE RANGE
-40℃ ~ 85℃ (NOTE1)
-10℃ TO 60℃(WITH PACKING)
4
4
RATING
VOLTAGE
AC 10V
0.5A
OPERATING OR
STORAGE HUMIDITY RANGE
95% MAXIMUM
(NON-CONDENSING)
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT
ACCORDING TO DRAWING
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
IEC60512-2-1
OPEN VOLTAGE 20 mV AC MAX
TEST CURRENT 1mA
INITIALLY 100mΩ MAXIMUM (NOTE2)
INITIALLY 1000MΩ MINIMUM
X
-
INSULATION RESISTANCE MEASURE WITHIN 1 MINUTE AFTER APPLYING
500V DC
X
X
-
X
IEC60512-3-1
2
VOLTAGE PROOF
IEC60512-4-1
① NO FLASHOVER OR BREAKDOWN
② CURRENT LEAKAGE 1mA MAXIMUM
500Vrms AC IS APPLIED FOR 1 MINUTE
2
MECHANICAL CHARACTERISTICS
5,000 TIMES INSERTION AND WITHDRAWAL
SHALL BE MADE AT THE CYCLE RATE LESS
THAN 10 CYCLES PER 1MINUTE
NOTE : AFTER EACH 10 CYCLES STOP THE
INSERTION AND REST THE CONNECTOR
① CONTACT RESISTANCE:
AFTER TEST 50mΩ MAXIMUM CHANGE
MECHANICAL OPERATION FOR 5 TO 10 MINUTES.
[OFFICE ENVIRONMENT]
EIA364B class 1.1
X
-
CARD SURFACE SHALL BE CLEANED BY AIR
BLOW:
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
AT EACH 100 CYCLES INTERVAL(10 TIMES)
FROM START TO 1,000 CYCLES.
AT EACH 1,000 CYCLES INTERVAL(4 TIMES)
FROM 1,001 CYCLES TO 5,000CYCLES.
1
CARD INSERTION FORCE
CARD EJECTION FORCE
MEASURED BY APPLICABLE CARD AT 25±
3mm/min
3 TO 7N (NOTE3)
X
X
-
-
VIBRATION AND HIGH
FREQUENCY
IEC60512-6-4
FREQUENCY 10 TO 55 TO 10 Hz/min, SINGLE ① NO ELECTRICAL DISCONTINUITY OF 1us
AMPLITUDE 0.75mm FOR 2h IN X,Y,Z 3
DIRECTIONS, TOTAL 6h
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
2
2
ACCELERATION 490m/s2 STANDARD HOLDING
TIME 11ms, SEMI-SINE WAVE FOR 3 TIMES IN 3 ③ CONTACT RESISTANCE
DIRECTIONS, TOTAL 18 TIMES. AFTER TEST 50mΩ MAXIMUM CHANGE
SHOCK
IEC60512-6-3
X
-
3
REFERENCE DRAWING
REMARKS
DRAWN
DESIGNED
CHECKED
APPROVED
RELEASED
(NOTE1) : INCLUDE THE TEMPERATURE RISE BY CURRENT
(NOTE2) : CONTACT RESISTANCE INCLUDES CONDUCTOR RESISTANCE UNLESS
OTHERWISE SPECIFIED. THE TEST SHOULD BE DONE UNDER TEMP 15 TO 35℃.
AIR PRESSURE 86 TO 106kPA, RESLATIVE HUMIDITY 25 TO 85%.
(NOTE3) : IT MAY BE CHANGED ACCORDING TO THE TRAY/CARD MATERIAL AND
DIMENSIONS.
ENG
C.K.KIM
14.06.30
C.K.KIM
14.06.30
C.K.KIM
14.06.30
H.C.SONG
14.06.30
23.01.11
DEPT
1
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST X: APPLICABLE TEST
PART NO.
KP13B-SF-PEJ(800)
HIROSE KOREA CO.,LTD.
CODE NO.(OLD) DRAWING NO.
CL ELC4-631768
SPECIFICATION SHEET
CODE NO.
CL 6530-0002-9-800
1
2