描述
连接器类型:插头;线束品:无;PIN数:24;额定电流:3.0 A;(DC)额定电压:DC 250.0 V;(嵌合部分)列数:2;安装间距:1.0 mm;开口间距:2.0 mm;连接器长度(间距方

KM32-24DP-2H(BL)(800) 数据手册

 浏览型号KM32-24DP-2H(BL)(800)的Datasheet PDF文件第2页 
Description  
Description  
dd/mm/yy  
△NO  
△NO  
Designed Checked Approved dd/mm/yy  
Designed Checked Approved  
RE-4-2991  
(Change usage temperature range)  
1
2
P S W  
L J E  
B K S  
24/06/'21  
3
4
2
Applied specification  
Use temperature range  
- 40℃ ∼ + 85℃  
- 40℃ ∼ + 85℃  
Voltage  
Current  
DC 250 V  
3 A  
1
Specification  
Preservation temperature range  
Performance  
Clause  
Test Method  
Specification  
QT AT  
Appearance  
Appearance / By Scope(X10) or sense of sight and touch.  
No harmful crack, rust, burr, damage, deformation, discoloration etc.  
Measure force by inserting and disengaging the connector with terminal  
assembled at constant 50 mm/min speed.  
However, remove lock part when measuring disengage force.  
Conn' engage and  
disengage force  
7.6 kgf or less  
-
Insert terminal to housing, and fix housing of female connector to moving part  
a measuring  
Reverse insertion  
between housings  
It shall not be incorrectly inserted and flowed current between  
terminal by housing deformation on applying force of 10 kgf.  
of measuring instrument in reverse insertion direction. Set  
instrument to stop at force of 10 kgf and insert that.  
-
-
Reverse insertion  
between terminal and  
housing  
Crimp cable of maximum size on terminal and then insert it into housing by end  
of insulation barrel in the reverse direction.  
1.5 kgf or more  
1.5 kgf less  
Engage force between Measure the weight while inserting terminal into fixed housing at 50 mm/min  
speed.  
-
-
terminal and housing  
Combine housing only, fix the one side of housing in completely locked  
condition, and extend the other side in axial direction and 30 angle direction at  
a constant speed 50 mm/min. Then measure weight when lock structure is  
disengaged or destroyed.  
Strength of HSG Lock  
2 kgf or more  
Fix the housing after inserting crimped terminals. Extend one line of cable in  
axial direction at a speed of 50 mm/min at a position 50~100 mm away from  
crimped part, and measure weight when terminal is disengaged from the  
housing. When housing is fixed on the jig, do not fix the retainer on the jig.  
Terminal retention  
force  
4 kgf or more  
-
General  
requirements  
Fix the crimped terminal, and draw the cable at a position 50~100 mm away  
Crimp strength  
Voltage drop  
from crimped part in axial direction at 100 mm/min speed. Then measure the 6 kgf or more  
weight when cable is cut or disengaged from the crimped part.  
-
-
Measure the circuit voltage drop (V) by sending voltage 20±5 mV, current  
10mA with terminal combined on the connector. Then calculate a voltage drop  
in terminal by subtracting cable resistance from the circuit voltage drop.  
Initial : 30 mΩ or less  
After endurance : 50 mΩ or less  
Measure resistance between neighbor terminals, and between terminal and  
housing surface with DC 500 V insulation resistance gauge with connector  
combined.  
Initial : 100 MΩ or more  
After endurance : 10 MΩ or more  
Insulation resistance  
Withstand voltage  
-
Apply AC 500 V for 1minute between neighboring terminals, and between  
housing surfaced of terminal, with connector combined.  
There shall be no insulation break.  
After endurance : 40°C or less  
Apply basic current of the connector with electrodes in series in the room free  
from wind (normal temperature). And measure a temperature of crimped part  
after reaching saturation temperature. Then calculate a temperature of crimped  
part by subtracting ambient temperature from the temperature.  
Temperature rise  
-
-
It is instant short circuit, when 3.5 V or less voltage continues for 1 μs or more  
in gauge by applying 1 mA, 5 V open voltage. (instant short circuit evaluated in There shall be no 1 ㎲ or more instant short circuit.  
complex environment endurance test.)  
Instant short circuit  
Released  
Note  
Designed  
Drawn  
Checked Approved  
1) Temperature rise from applying an electric current are included.  
2) This product specification is for customer offer.  
K D H  
K D H  
R S M  
H G M  
A M C  
'16.8.12  
'16.8.12  
'16.8.12  
'16.8.12  
'23.11.09  
3) Opponent product must use specified opponent product.  
- QT: Confirmation Test, AT: Product Inspection ○: Using  
Part Name  
KM32-24DP-2H(BL) (800)  
Hirose Korea Corporation  
Product Code  
Old CL Code  
CL  
Drawing Code  
ELC3-632324  
1
2
6432-0035-2-800  

与KM32-24DP-2H(BL)(800)相关器件

型号 品牌 获取价格 描述 数据表
KM32-24DS-HU(BL)(800) HRS

获取价格

连接器类型:插座;线束品:无;PIN数:24;额定电流:3.0 A;(DC)额定电压:DC
KM32-2P-2H(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:2;额定电流:3.0 A;(DC)额定电压:DC
KM32-2P-2V(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:2;额定电流:3.0 A;(DC)额定电压:DC
KM32-2S-HU(BL)(800) HRS

获取价格

连接器类型:插座;线束品:无;PIN数:2;额定电流:3.0 A;(DC)额定电压:DC
KM32-3P-2H(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:3;额定电流:3.0 A;(DC)额定电压:DC
KM32-3S-HU(BL)(800) HRS

获取价格

连接器类型:插座;线束品:无;PIN数:3;额定电流:3.0 A;(DC)额定电压:DC
KM32-4P-2H(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:4;额定电流:3.0 A;(DC)额定电压:DC
KM32-4P-2V(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:4;额定电流:3.0 A;(DC)额定电压:DC
KM32-4S-HU(BL)(800) HRS

获取价格

连接器类型:插座;线束品:无;PIN数:4;额定电流:3.0 A;(DC)额定电压:DC
KM32-6P-2H(BL)(800) HRS

获取价格

连接器类型:插头;线束品:无;PIN数:6;额定电流:3.0 A;(DC)额定电压:DC