5秒后页面跳转
KLLU4000 PDF预览

KLLU4000

更新时间: 2024-10-29 03:48:15
品牌 Logo 应用领域
力特 - LITTELFUSE 电熔丝电路保护
页数 文件大小 规格书
3页 190K
描述
General Purpose Fuses

KLLU4000 技术参数

生命周期:ActiveReach Compliance Code:unknown
ECCN代码:EAR99风险等级:5.71
Is Samacsys:N熔断特性:TIME DELAY
主体高度:101.6 mm主体长度或直径:146.1 mm
电路保护类型:ELECTRIC FUSE保险丝类:L
安装特点:INLINE/HOLDER物理尺寸:146.1mm x 101.6mm
额定分断能力:200000 A额定电流:4000 A
额定电压:600 V额定电压(交流):600 V
参考标准:CSA; UL表面贴装:NO
端子形状:TAB/BLADEBase Number Matches:1

KLLU4000 数据手册

 浏览型号KLLU4000的Datasheet PDF文件第2页浏览型号KLLU4000的Datasheet PDF文件第3页 
General Purpose Fuses  
KLLU Class L Fuses  
600 VAC • Time-Delay • 601 – 4000 Amperes  
Applications  
Service switches  
Switchboard mains and feeders  
Bolted pressure contact switches  
Motor control center mains  
Large motor branch circuits  
UL Listed series rated protection for molded case circuit breaker  
panelboards and loadcenters. See panelboard manufacturers’  
literature for recommended fuse rating.  
Safety  
• 200,000 A.I.R. — Provides reliable interruption of all overcurrents up  
to 200,000 amperes.  
• When used for motor branch circuit protection, KLLU fuses may be  
sized close to the motor full load current, providing excellent protection  
to branch circuit conductors, motor control equipment and motors.  
Longer Equipment Life  
• Current-Limiting — Reduces short-circuit damage to systems and  
equipment.  
• Reduced downtime.  
• Ten second minimum time-delay at 500% current eliminates  
needless downtime caused by heavy starting currents of large  
motors and other inductive loads.  
• Selective coordination — KLLU fuses coordinate well with other  
Class L fuses and with all current-limiting Littelfuse fuses rated 600  
amps or less. This means less time spent trying to locate short-  
circuits or overloaded equipment, because only the fuse immediately  
on the line side of the affected circuit opens.  
KLLU series UL Listed, time-delay, Class L fuses are quality fuses,  
developed to provide a somewhat lower priced alternate to the  
POWR-PRO® KLPC series fuses. KLLU series fuses meet or exceed  
all UL requirements for Class L fuses. For superior protection and  
performance, specification-grade POWR-PRO KLPC series fuses are  
the recommended fuse. Complete information on KLPC fuses may  
be found in the POWR-PRO Fuse section of this catalog.  
Easy To Use  
• 200,000 A.I.R. rating minimizes need for short-circuit calculations,  
while meeting present and future system requirements.  
• KLLU fuse time-current characteristics closely match typical time-  
current curves of circuit breakers. Although fuse/circuit breaker systems  
can seldom be 100% coordinated, KLLU series fuses permit use of a  
wider range of breaker setting than fast acting Class L fuses.  
Excellent protection for a single breaker or a group of breakers.  
Specifications  
Ampere Ratings  
Voltage Ratings:  
AC: 600 Volts  
DC: Contact factory  
601  
650  
700  
750  
800  
900  
1000  
1200  
1350  
1400  
1500  
1600  
1800  
2000  
2500  
3000  
3500  
4000  
Interrupting Ratings:  
Ampere Range:  
Approvals:  
200,000 amperes rms symmetrical  
601 – 4000 amperes  
Standard 248-10, Class L  
UL Listed (File No: E81895)  
CSA Certified (File No: LR29862)  
Example part number (series & amperage): KLLU 1000  
26  
w w w . l i t t e l f u s e . c o m  
© 2005 Littelfuse POWR-GARD Products Catalog  

与KLLU4000相关器件

型号 品牌 获取价格 描述 数据表
KLLU601 LITTELFUSE

获取价格

General Purpose Fuses
KLLU601.X LITTELFUSE

获取价格

Electric Fuse
KLLU650 LITTELFUSE

获取价格

General Purpose Fuses
KLLU650.X LITTELFUSE

获取价格

Electric Fuse
KLLU700 LITTELFUSE

获取价格

General Purpose Fuses
KLLU700.X LITTELFUSE

获取价格

Electric Fuse
KLLU750 LITTELFUSE

获取价格

General Purpose Fuses
KLLU750.X LITTELFUSE

获取价格

Electric Fuse
KLLU800 LITTELFUSE

获取价格

General Purpose Fuses
KLLU800.X LITTELFUSE

获取价格

Electric Fuse