FLAT TYPE POWER RELAY
JV-RELAYS
22
.866
16
.630
FEATURES
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height)
(.630×.866×.429 inch)
10.9
.429
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
mm inch
SPECIFICATIONS
Contact
Characteristics
High capacity
type
High
sensitivity type
Standard type
Max. operating speed
20 cpm
Arrangement
1 Form A
1 Form C
50 mΩ
Silver alloy
1 Form A
1 Form A
Initial insulation resis-
tance*1
Min. 100 MΩ
(at 500 V DC)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Betweenopen
contacts
1,000 Vrms
for 1 min.
Initial
Contact material
break-
down
voltage*2
Between con-
tacts and coil
1,500 Vrms
for 1 min.
Nominal switching
capacity
10 A 125 V AC (N.O.)
6 A 125 V AC (N.C.)
10 A 125 V AC
1,250 VA
16 A 125 V AC 10 A 125 V AC
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
1,250 VA (N.O.)
750 VA (N.C.)
Operate time*3
(at nominal voltage)
Max. switching power
Max. switching voltage
Max. switching current
2,000 VA
16 A
1,250 V
10 A
Rating
(resistive)
125 V AC
Release time (without diode)*3
(at nominal voltage)
10 A (N.O.)
6 A (N.C.)
Approx. 4 ms
10 A
Max. 65°C with nominal
coil voltage across
coil and at nominal
switching capacity
Expected life (min. ope.)
Mechanical at (180 cpm)
107
Temperature rise
(at 50°C)
Sealed type
105
105
105
3×104
5×104
Electrical at resistive
(at 20 cpm)
(at rated load)
Functional*4
Shock
Min. 98 m/s2 {10 G}
Flux-resistant
type
3×105
105
105
Min. 980 m/s2
{100 G}
Destructive*5
resistance
Coil
1 Form A type
1 Form C type
10 to 55 Hz
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
Standard type
Functional*6 at double amplitude
of 1.0 mm
200 mW (up to 48 V coil type)
600 mW (100 V coil type)
Nominal
operating
power
Vibration
resistance
High capacity type
High sensitivity type
—
—
10 to 55 Hz
at double amplitude
of 1.6 mm
100 mW
Destructive
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage"section
*2 Detection current: 10mA
Conditions for opera- Ambient –40°C to +70°C*8
tion, transport and
temp.
–40°F to +158°F
storage*7
*3 Excluding contact bounce time
(Not freezing and
condensing at low
temperature)
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
Humidity
5 to 85%R.H.
*
7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Unit weight
Approx. 8 g .282 oz
*8 100V type: –40 to + 60°C –40 to + 140°F
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Ex. JV
1a
P
F
S
12V
Contact arrangement
Rating
Protective construction
Sensitivity
Nil: Standard type
Coil voltage (DC)
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
5, 6, 9, 12, 18,
24, 48, 100V
1: 1 Form C
1a: 1 Form A
Nil: Standard type
P: High capacity type*
Nil: Sealed type
F: Flux-resistant type
(1 Form A: 100 mW)
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
* Only for 1 Form A type