VDE
ULTRA-MINIATURE
PC BOARD TYPE
POWER RELAY
JS RELAYS
FEATURES
• Ultra-miniature size with universal terminal footprint
22
.866
16
.630
• High contact capacity: 10 A
16
.630
• Class B coil insulation type available
• TV-5 type available
1 Form A type → TV-5
1 Form C type → TV-5 (N.O. side only)
• VDE,TÜV also approved
mm inch
• Sealed construction for automatic cleaning
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A, 1 Form C
100 mΩ
Max. operating speed
20 cpm
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Initial insulation resistance
Min. 100 MΩ (at 500 V DC)
750 Vrms for 1 min.
Initial
breakdown
voltage*1
Between open contacts
Between contacts and coil
Contact material
Silver alloy
1,500 Vrms for 1 min.
Approx. 10 ms
10 A 250 V AC
10 A 125 V AC
6 A 277 V AC
Nominal switching capacity
Operate time*2
(at nominal voltage)
Release time(without diode)*2 (at nominal
voltage)
Rating
(resistive
load)
Max. switching power
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
2,500 VA
250 V AC, 100 V DC
10 A (AC), 5 A (DC)
107
Approx. 10 ms
Temperature rise (at nominal voltage)
Max. 35°C
Functional*3
Destructive*4
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
Approx. 98 m/s2 {10 G},
10 to 55 Hz at double
amplitude of 1.6 mm
Approx. 117.6 m/s2 {12 G},
10 to 55 Hz at double
amplitude of 2 mm
Shock resistance
Electrical at 10 A 125 V AC,
6 A 277 V AC resistive
(at 20 cpm)
Expected
life
(min.ope.)
105
Functional*5
5 × 104
(No contact only)
Vibration
resistance
10 A 250 V AC resistive
(at 20 cpm)
Destructive
Coil
Nominal operating power
360 mW
Conditions for operation,
transport and storage*6
(Not freezing and condens-
ing at low temperature)
Ambient
temp.*7
–40°C to +85°C
–40°F to +185°F
Remarks
* Specifications will vary with foreign standards certification ratings.
Humidity
5 to 85% R.H.
*1 Detection current: 10mA
*2 Excluding contact bounce time
Unit weight
Approx.12 g .423 oz
*3 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*4 Half-wave pulse of sine wave: 6ms
*5 Detection time: 10µs
*6 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
*7 When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
TYPICAL APPLICATIONS
1. Home appliances
Air conditioner, heater, etc.
2. Automotive
3. Office machines
PPC, facsimile, etc.
4. Vending machines
Power-window, car antenna, door-lock,
etc.
76