APPLICABLE STANDARD
-25 C TO +85 C
-10 C TO +60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 100 V , DC 140 V
5 A
APPLICABLE CABLE
CURRENT
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
MARKING
ELECTRIC CHARACTERISTICS
-
-
X
X
10
m MAX.
CONTACT RESISTANCE
CONTACT SHALL BE MEASURED AT DC
1
A
1000 M MIN.
INSULATION RESISTANCE
500 V DC.
-
X
VOLTAGE PROOF
1000 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT RETENTION FORCES
APPLYING A PULL THE WIRE AFTER THE APPLICABLE CRIMPED
50 N MIN.
X
X
-
-
CONTACT IS ASSEMBLE THE BODY.
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR.
INSERTION AND WITHDRAWAL FORCES
LOCKING DEVICE WITH UNLOCK
CONTACT RESISTANCE: 10
:
34 N MAX
m MAX.
MECHANICAL OPERATION
500 TIMES INSERTIONS AND EXTRACTIONS.
X
X
-
-
① NO ELECTRICAL DISCONTINUITY OF 10 s.
VIBRATION
SHOCK
FREQUENCY: 10 → 55 (Hz), SINGLE AMPLITUDE 0.75 mm,
AT 2 h , FOR 3 DIRECTIONS.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
AT 490 m/s2 DURATIONS OF PULSE 11 ms AT 3 TIMES FOR
6 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
X
X
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
(STEADY STATE)
② INSULATION RESISTANCE: 100 MΩ MIN
(AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 1000 MΩ MIN.
RAPID CHANGE OF TEMPERATURE TEMPERATURE -40→ R/T(1) → +100 → R/T ℃
X
-
TIME 30 →10 TO 15→ 30 →10 TO 15 min UNDER 5 CYCLES. ② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
EXPOSED IN 5 SALT WATER SPRAY FOR 500 h.
EXPOSED AT +100 ℃ , 96 h.
CORROSION SALT MIST
DRY HEAT
NO HEAVY CORROSIN RUIN THE FUNCTION.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
X
X
-
-
COLD
EXPOSED AT -40 ℃ , 96 h.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO WATER PENETRATION INSIDE CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR.
X
X
-
-
(2)
SEALING
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
AIRTIGHTNESS(2)
APPLY AIR PRESSURE 18 kPa FOR 30 S TO INSIDE
CONNECTOR.
-
X
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HY.KOBAYASHI
HY.KOBAYASHI
TH.KAMEYA
18.02.26
18.02.26
18.02.24
18.02.14
NOTES (1) R/T : ROOM TEMPERATURE.
(2) SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER MATED CONDITION WITH AN
APPLICABLE CONNECTOR.
(3) ABOVE SPECIFICATIONS ARE FOR THE STATE THAT APPLICABLE CRIMP
CONTACTS ARE ASSEMBLED.
MK.INOUE
Unless otherwise specified, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-110660-31-00
JR16WR-10PC(31)
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL114-2130-8-31
FORM HD0011-2-1