APPLICABLE STANDARD
Operating
Storage Temperature
Range
-35C to +85C
-10C to +60C
Temperature Range
AC 250 V, DC 350 V
10 A
Rating
Voltage
Current
Applicable Cable
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
X
X
Contact Resistance
Insulation Resistance
Measured at DC 1A.
5 m MAX.
Measured at 500 V DC.
1000 M MIN.
Voltage Proof
1000 V AC applied for 1 min. (Unmated)
4000 V AC applied for 1 min. (Mated)
X
X
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Contact Insertion and
Extraction Forces
Measured with a φ1.57 ± 0.003 steel gauge.
Insertion and extraction forces: 0.49 N MIN.
X
-
Mating and Unmating Forces Measured with an applicable connector.
Mating and unmating forces : 13.7 N MAX.
(Without lock)
X
X
-
-
Contact resistance: 5 m MAX.
Mechanical Operation
Vibration
Mated and unmated 500 times.
Frequency: 10 Hz to 55 Hz to 10 Hz
Single amplitude: 0.75 mm
1) No electrical discontinuity of more than 10 s.
X
-
2) No damage, cracks or looseness of parts.
Performed over 10 cycles, at 5 minutes per cycle, in each of
three mutually perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
1) No electrical discontinuity of more than 10 s.
Performed 3 times in each of three mutually perpendicular
directions.
2) No damage, cracks or looseness of parts.
X
X
-
-
ENVIRONMENTAL CHARACTERISTICS
1) Insulation resistance: 10 M MIN.
(At high humidity)
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
95% for 96 hours.
2) Insulation resistance: 100 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
Rapid Change of Temperature Temperature: -40 → R/T(2) → +100 → R/T C
Time: 30 → 2 to 3 → 30 → 2 to 3 min
for 5 cycles.
1) Insulation resistance: 1000 M MIN.
2) No damage, cracks or looseness of parts.
X
X
-
-
Subjected to 5% salt spray for 500 hours.
Corrosion Salt Mist
No heavy corrosion which impairs functionality.
No damage, cracks or looseness of parts.
No damage, cracks or looseness of parts.
Dry Heat
Subjected to +100℃ for 96 hours.
X
X
X
-
-
-
Cold
Subjected to -40℃ for 96 hours.
Resistance to Soldering
Heat
Soldering iron is placed to the soldering surface for 3 to 4 s.
(Iron tip temperature +380 ± 10℃)
No deformation or excessive looseness of terminals.
Solderability
Soldering iron is placed to the soldering surface for 2 to 3 s. Soldering surface shall be free from pin-holes, de-
X
X
X
-
-
-
(Iron tip temperature +350 ± 10℃)
wetted and un-wetted areas and other defects.
No water penetration into the connector.
Sealing(3)
Subjected to a depth of 1.8 m for 48 hours.
Air Tightness(3)
18 kPa of air pressure applied to the inside of the mated
connector for 30 seconds.
No air bubbles emitted from the inside of the
connector.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
NOTES
APPROVED
CHECKED
DESIGNED
HY.KOBAYASHI
HY.KOBAYASHI
TY.SUZUKI
17.05.10
17.05.10
17.05.10
(1) This product satisfies the specifications specified below (IEC 60664 (JIS C 60664))
• At AC/DC 250V: Overvoltage Category III, Minimum Creepage Distance: 2mm MIN.
• Over DC 250V: Overvoltage Category II, Minimum Creepage Distance: 2mm MIN.
(2) R/T:Room Temperature
DRAWN
THOMAS FORAN
17.05.10
(3) Sealing and Air Tightness are tested in mated condition with an applicable connector.
Unless otherwise specified, refer to IEC 60512. (JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-119038-00-00
JR13WPFA-3SA
PART NO.
CODE NO.
SPECIFICATION SHEET
0
1/1
HIROSE ELECTRIC CO., LTD.
CL114-2101-0-00
△
FORM HD0011-2-1