130 Watts
xppower.com
JPP130 Series
•
•
•
•
•
•
•
High Power Density
Small Footprint
Up to Five DC Outputs
Wide Adjustment on Two Outputs
Short Circuit Protection with Auto Recovery
Power Fail Signal
Active Power Factor Correction
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
• 90-264 VAC
Efficiency
Isolation
• 75% typical
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 7.2 W/In3
• 2.10 A at 115 VAC, 1.10 A at 230 VAC
• 35 A at 115 VAC, 70 A at 230 VAC
• 0.98 typical
Power Density
Signals
• PFD = TTL Level (see note 5)
• 200 kHrs per MIL-STD-217F
MTBF
Output
Output Voltage
• See table
Environmental
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• User adjustable (see note 3)
• 2% except V2: 3%
• See note 4
Operating Temperature • -10 ºC to +60 ºC, derate from 100% load
at +40 ºC to 50% load at +60 ºC
Cooling
• 10 CFM
Start Up Delay
• 2 s max
Operating Humidity
Storage Temperature
Shock
• 5-95% RH, non-condensing
• -40 ºC to + 85 ºC
Start Up Rise Time
Hold Up Time
• 12 ms max
• 15 ms min
• 20 G on 3 axis, 3 times each
Line Regulation
Transient Response
•
0.5% max
Vibration
• 10-55 Hz, 0.15 at 1 octave/min for
30 mins on each 3 axis
• 4% max. deviation, 500 µs recovery time
for a 25% load change
Ripple & Noise
• 65 mV for V1, 1% pk-pk on all other
outputs, 20 MHz BW
EMC & Safety
Emissions
• EN55022 FCC part 15 and VCCI level B
conducted and level A radiated
Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal
Temperature
Coefficient
• 0.04% / ºC
Harmonic Currents
Voltage Flicker
EFT/Burst
• EN61000-3-2
• EN61000-3-3
Remote Sense
• On 3.3 V output only: Compensates for
up to 0.5 V drop
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
Safety Approvals
• UL60950, CSA C22.2 No. 60950,
EN60950, CE Mark LVD