80-160 Watts
JPM Series
xppower.com
•
•
•
•
•
•
•
Low Cost
High Reliability
Power Factor Corrected
Suitable for Battery-charging Applications
Low Ripple & Noise
125% Rating at 230 VAC
Optional Remote On/Off
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 85-264 VAC (120-370 VDC)
Efficiency
Isolation
• See tables
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• JPM80: 0.7 A max at 230 VAC
JPM120: 1.1 A max at 230 VAC
JPM160: 1.4 A max at 230 VAC
MTBF
• >183 kHrs per MIL-HDBK-217F (+25 °C)
Inrush Current
Power Factor
• 40 A at 230 VAC cold start
• >0.9
Environmental
Earth Leakage Current • <2 mA at 230 VAC
Operating Temperature • -10 °C to +60 °C, see derating curves
Output
Cooling
• JPM80 & JPM120 convection-cooled,
JPM160 includes internal fan
Output Voltage
• See tables
• +10%, -5%
Output Voltage Trim
Initial Set Accuracy
Start Up Delay
Operating Humidity
Storage Temperature
Vibration
• 20-90% RH, non-condensing
• -20 °C to +85 °C
•
2%
• 600 ms max
• 30 ms max
• 25 ms min
• 2 g, 10-500 Hz, 10 minꢀcycle for 60
minutes each axis
Start Up Rise Time
Hold Up Time
EMC & Safety
Line Regulation
Load Regulation
Ripple & Noise
•
0.5%
Emissions
• EN55022 (CISPR22), level B conducted
EN55022 (CISPR22), level B radiated
• See tables
• See tables
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2
Overvoltage Protection • 110-135% Vnom, recycle input to reset
• EN61000-3-3
Overtemperature
Protection
• Shuts down at +95 °C 5 °C (measured
internally) with auto recovery, only on
JPM120 & JPM160
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 Vꢀm Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 Aꢀm Perf Criteria A
Overload Protection
• 105-150% constant current, auto recovery
Temperature
Coefficient
•
0.05%ꢀ°C
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Remote On/Off
• 4-10 VDC On, <0.8 VDC Off, optional.
Add suffix ‘R’ to model number
• EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms,
Perf Criteria A, B, B
Safety Approvals
• EN60950-1-1:2001, UL60950-1,
CSA22.2 No. 60950-1, CE Mark LVD