5秒后页面跳转
JM1AN-ZTM-DC6V PDF预览

JM1AN-ZTM-DC6V

更新时间: 2024-09-22 03:07:39
品牌 Logo 应用领域
NAIS 继电器功率继电器
页数 文件大小 规格书
4页 121K
描述
COMPACT POWER RELAY FOR INDUCTIVE LOAD

JM1AN-ZTM-DC6V 数据手册

 浏览型号JM1AN-ZTM-DC6V的Datasheet PDF文件第2页浏览型号JM1AN-ZTM-DC6V的Datasheet PDF文件第3页浏览型号JM1AN-ZTM-DC6V的Datasheet PDF文件第4页 
VDE  
COMPACT POWER RELAY  
FOR INDUCTIVE LOAD  
JM-RELAYS  
30.4  
16  
• Excellent contact welding resistance  
High contact pressure, a forced opening  
mechanism, and a forced wiping  
mechanism realizes an excellent contact  
welding resistance.  
• Flux resistance mechanism  
The terminal area is plugged with resin to  
prevent flux seepage during PCB mount-  
ing. (TMP type)  
1.197  
.630  
26.5  
1.043  
31  
1.220  
• Conforms to the various safety stan-  
dards  
UL, CSA approved.  
28.5  
1.122  
• High breakdown voltage and surge  
resistant relay  
16.8  
.661  
Slim TMP type  
More than 6.4 mm .252 inch maintained  
for the insulation distance between con-  
tacts and coil, and the breakdown voltage  
between contacts and coil is 5,000 V for 1  
minute. In addition, the surge resistance  
between contacts and coil is greater than  
10,000 V.  
V, VDE under application.  
• The line up can support economical  
mounting methods.  
31  
1.220  
28.5  
1.122  
Flat TM type  
The relay are equipped with a drive termi-  
nal (coil terminal) on one side for PCBs,  
and a load terminal (tab terminal #250) on  
the reverse side. The line up includes the  
TM type which can be attached directly to  
the PCB composing a drive circuit, and  
the TMP type which supports economical  
wiring.The TMP type can also be directly  
attached, and a high capacity load can be  
wired to the tab terminal.  
17.2  
.677  
mm inch  
Flat TMP type  
• Resistant to external force  
An absorber mechanism is used on the  
load terminals, giving a large improve-  
ment in characteristics variations caused  
by the external force during FASTON  
placement/removal.  
FEATURES  
• Compact, high-capacity, and resis-  
tant to inductive loads  
The relay is a compact 16×30.4×26.5 mm  
.630×1.197×1.043 inch. It can control an  
inductive load (cosϕ = 0.7) with inrush  
current of 70 A and steady state current of  
20 A.  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
1 Form A  
Max. operating speed  
180 cpm  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
30 mΩ  
(Cd free type: 100 m)  
Initial insulation resistance*1  
Min. 100 M(at 500 V DC)  
Between open  
1,000 Vrms for 1 min.  
Contact material  
Silver alloy  
20 A 250 V AC  
5,000 VA  
250 V AC  
20 A  
contacts  
Initial  
breakdown  
voltage*2  
Nominal switching capacity  
Between con-  
tacts  
Rating  
(resistive  
load)  
5,000 Vrms for 1 min.  
Max. switching power  
and coil  
Max. switching voltage  
Surge voltage between con-  
tact and coil*3  
Operate time*4  
(at nominal voltage)(at 20°C)  
Release time (without diode)*4  
Min. 10,000 V  
Max. switching current  
Mechanical (at 180 cpm)  
106  
Max. 20ms (Approx. 8 ms)  
Max. 10ms (Approx. 3 ms)  
Resistive load 20 A, 250  
V AC (cosϕ = 1)  
105  
Inrush 70 A, Steady  
20 A (250 V AC  
cosϕ = 0.7)  
(at nominal voltage)(at 20°C)  
Expected  
life (min.  
ope.)  
Electrical  
Life  
(at 20 cpm)  
105  
Max. 55°C (Contact switching current:  
20 A/voltage applied to coil: 100%V)  
Temperature rise (at 60°C)  
Inductive  
load  
Inrush 80 A, Cut-off  
80 A (When the  
motor is locked) (250  
V AC cosϕ = 0.7)  
Functional*5  
Shock  
Min. 98 m/s2 {10 G}  
Min. 980 m/s2 {100 G}  
1.5×103  
resistance  
Destructive*6  
10 to 55 Hz at double  
amplitude of 1.6 mm  
Functional*7  
Vibration  
Coil  
resistance  
10 to 55 Hz at double  
amplitude of 2 mm  
Destructive  
Nominal operating power  
900 mW  
Remarks  
Conditions for operation,  
transport and storage*8  
(Not freezing and condens-  
ing at low temperature)  
Ambient  
temp.  
–40°C to +60°C  
–40°F to +140°F  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as "Initial breakdown voltage" section  
*2 Detection current: 10mA  
Humidity  
5 to 85% R.H.  
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981  
*4 Excluding contact bounce time  
Slim TMP  
Approx. 28 g .99 oz  
Approx. 32 g 1.13 oz  
Approx. 33 g 1.16 oz  
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs  
*6 Half-wave pulse of sine wave: 6ms  
Unit weight Flat TMP  
Flat TM  
*7 Detection time: 10µs  
*8 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 24).  
114  

与JM1AN-ZTM-DC6V相关器件

型号 品牌 获取价格 描述 数据表
JM1AN-ZTM-DC6V-F PANASONIC

获取价格

Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM1AN-ZTM-DC9V NAIS

获取价格

COMPACT POWER RELAY FOR INDUCTIVE LOAD
JM1AN-ZTM-DC9V-F PANASONIC

获取价格

Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM1AN-ZTMP-DC12V NAIS

获取价格

COMPACT POWER RELAY FOR INDUCTIVE LOAD
JM1AN-ZTMP-DC12V-F PANASONIC

获取价格

Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM1AN-ZTMP-DC24V NAIS

获取价格

COMPACT POWER RELAY FOR INDUCTIVE LOAD
JM1AN-ZTMP-DC24V-F PANASONIC

获取价格

Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM1AN-ZTMP-DC48V NAIS

获取价格

COMPACT POWER RELAY FOR INDUCTIVE LOAD
JM1AN-ZTMP-DC48V-F PANASONIC

获取价格

Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM1AN-ZTMP-DC5V NAIS

获取价格

COMPACT POWER RELAY FOR INDUCTIVE LOAD