VDE
SLIM TYPE POWER RELAY
FEATURES
JK-RELAYS
11
.433
• Compact & Slim design: 11.0 mm (length) × 21.4 mm (width) × 15.7 mm (height)
(.433×.843×.618 inch)
21.4
.843
15.7
.618
• High capacity type (8 A) available
• Surge resistance: Min. 8,000 V between contact and coil
• High sensitivity: 200 mW nominal operating power
• Sealed type available
• VDE,TÜV, SEMKO also approved
mm inch
SPECIFICATIONS
Contact
Characteristics
High capacity
type
Max. operating speed
Initial insulation resistance*1
20 cpm
Type
Standard type
Min. 100 MΩ at 500 V DC
750 Vrms for 1 min.
Arrangement
1 Form A
Initial
breakdown
voltage*2
Between open contacts
Between contact and coil
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 mΩ
2,000 Vrms for 1 min.
Contact material
Silver alloy
Surge voltage between contact and coil*3
Operate time*4 (at nominal voltage)
Min. 8,000 V
Approx. 4 ms
Nominal switching
3 A 30 V DC
5 A 30 V DC
capacity
Rating
3 A 125 V AC 8 A 125 V AC
Release time*4 (at nominal voltage)
(without diode)
Approx. 2 ms
90 W,
150 W,
Max. switching power
(resistive
load)
500 VA
1,250 V A
Max. 45°C with nominal coil
voltage and at maximum
allowable contact current
Temperature rise
(ambient temperature: 70°C)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
250 V AC, 110 V DC (0.3 A)
3 A
8 A
Functional*5
Shock resistance
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
5×106
Expected
life (min.
operations)
Destructive*6
Electrical (at 20 cpm)
(at rated load)
105
10 to 55 Hz at double
amplitude of 1.6 mm
Functional*7
Vibration resistance
Coil
10 to 55 Hz at double
amplitude of 2 mm
Destructive
Nominal operating
power
Standard and high capacity type
200 mW
Conditions for operation,
transport and storage*8
(Not freezing and condensing
at low temperature)
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
Humidity
5 to 85% R.H.
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Unit weight
Approx. 7 g .25 oz
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
TYPICAL APPLICATIONS
ORDERING INFORMATION
• Home appliances
Ex. JK 1a
P
F
12 V
Microwave ovens, Air conditioners
• Office equipment
Photocopiers, Facsimiles
• Industrial machines
NC machines
Protectiive
constructiion
Coil voltage
(DC)
Contact capacity
Nil: Standard 3 A
P: High capacity
8A
Nil: Sealed type
F: Flux-resis-
tant type
3, 5, 6, 9, 12, 18,
24, 48 V
Notes: 1. For TV-5 rated type, add sufix “-TV”.
1. For detailed specifications, please consult us.
2. Standard packing: Carton: 100 pcs.; Case: 500 pcs.
UL/CSA, VDE approved type is standard.
292