VDE
COMPACT ECONOMICAL
POWER RELAYS
JE-X
RELAYS
FEATURES
• Compact size - Height Max. 18.7 mm .736 inch
lower than JY relay (22.5 mm) (.886 inch)
22
.866
14
.551
18.7
.736
• High contact capacity — 5A 125 V AC
• Safety-oriented between coil and contact terminals
• All plastic materials: UL flame retardance 94V-0
• VDE,TÜV also approved
mm inch
TERMINAL LAYOUT
Distance of 9.16 mm .360 inch between common and coil termi-
nals and 8.9 mm .350 inch between contacts give room to the
land diameter width when the relay is mounted on PC board, and
allow design of patterns with insulation distances of 6 mm .236
inch between common and coil and 5.9 mm .232 inch between
contacts.
• 3 mm .118 inch or more insulation distance for close
mounting can be kept easily with JE-X relays.
0.9
.035
R1
R2
3 dia.
9.16
.118 dia.
.361
8.9
8.9
3
.350
.350
.118
6.16
3 dia.
N.O.
.243
.118 dia.
Coil
Coil
4.45
.175
In case of 3 mm
.118 inch land
diameter
3 dia.
N.C.
N.O.
N.C.
N.O.
5.9
.118 dia.
.233
4.45
.175
1.3 dia.
.051 dia.
N.C.
COM
mm inch
mm inch
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
1 Form C
Max. operating speed
Initial insulation resistance*1
20 cpm (at 70°C)
Min. 100 MΩ (at 500 V DC)
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
100 mΩ
Between open contacts
750 Vrms
Initial
Contact material
Silver alloy
breakdown
Between contacts and
coil
1,500 Vrms
voltage*2
Nominal switching
capacity
5 A 30 V DC, 5 A 125 V AC,
3A 250 V AC
Surge voltage between coil
and contact*3
Operate time*4 (at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Rating
Min. 5,000 V
Approx. 10 ms
Approx. 2 ms
Max. switching power
(resistive
750 VA, 150 W
250 V AC, 30 V DC
5 A
load)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
5×106
Expected
life (min.
operations)
Max. 45°C with nominal coil
voltage and at nominal
switching capacity
Electrical (at 20 cpm)
(at rated load)
105
Temperature rise (at 70°C)
Coil
Functional*5
Shock resistance
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
Destructive*6
Minimum operating power
Nominal operating power
Remarks
196 mW
400 mW
Functional*7
Vibration resistance
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
Destructive
*3 Wave is standard shock voltage of 1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Conditions for operation,
transport and storage*8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
*5 Half-wave pulse of sine wave: 6ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
Humidity
5 to 85% R.H.
*7 Detection time: 10µs
Unit weight
Approx. 9.2g .32 oz
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.