VDE
JC
COMPACT POWER RELAYS
JC RELAYS
FEATURES
• High inrush current capability
1 Form A: 163 A inrush (TV-8)
2 Form A: 111 A inrush (TV-5)
30.0
1.181
19.0
.748
30.0
1.181
19.0
.748
19.0
.748
30.4
1.197
• High dielectric withstanding for
transient protection:
JC can withstand 10,000 V surge in µs
between coil and contact.
32.4
1.276
32.9
1.295
• Electrical life:
PC board type
1 Form A: 105 ope. at 15 A 250 V AC
resistive load
2 Form A: 105 ope.
at 10 A 250 V AC resistive load
Plug-in type
45.0
1.772
TM type
• UL/CSA, VDE,TÜV, SEMKO also
mm inch
approved.
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
2 Form A
Maximum operating speed
20 cpm.
Initial insulation resistance*1
Min. 100 MΩ at 500 V DC
2,000 V rms for 1 min.
2,000 Vrms for 1 min.
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 mΩ
(Cd free type: 100 mΩ)
Silver alloy
Between open contacts
Contact material
Initial
breakdown
voltage*2
Between contacts sets
Contact force, min.
Maximum switching power
30 g
Between contacts and
coil
3,750 VA
250 V AC
15 A
2,500 VA
250 V AC
10 A
4,000 Vrms for 1 min.
Max. 30 ms
Rating
Maximum switching voltage
(resistive
Operate time*3
(at nominal voltage)
Release time(without diode)*3
(at nominal voltage)
Max. switching current
load)
Min. switching capacity#1
100 mA, 5 V DC
5×106
Max. 10 ms
Mechanical
Expected
life (min.
operation)
10 A 250 V AC
5A 250 V AC
105
—
105
Electrical
(resistive)
Temperature rise
(at nominal voltage)
Max. 55°C
—
Functional*4
Destructive*5
resistance
196 m/s2 {20 G}
980 m/s2 {100 G}
Coil
Shock
Nominal operating power
900 mW
1,000 mW
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Functional*6
Vibration
resistance
Remarks
Destructive
* Specifications will vary with foreign standards certification ratings.
*1 Measurement of same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
Conditions for operation,
transport and storage*7
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–50°C to +60°C
–58°F to +140°F
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Humidity
5 to 85%R.H.
*6 Detection time: 10µs
Unit weight
Approx. 31 g 1.09 oz
*7 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
TYPICAL
ORDERING INFORMATION
APPLICATIONS
Ex. JC
1a
F
TM
DC12V
F
Automatic garage door openers
Microwave ovens
Dryers
Contact
arrangement
Mounting classification Coil voltage
Environmental support
Vending machines
Copiers
Nil: PC board terminal
DC 5, 6, 12,
F: RoHS Directive conforming type
(AgSnO2 type)
1a: 1 Form A
2a: 2 Form A
S: Plug-in terminal
24, 48 V
Air conditioners
Stereo equipment
TV sets
TM: Top mounting
Nil: RoHS Directive non-conforming type
(AgCdO type)
(Notes) 1. TV rated types available 1 Form A: TV-8; 2 Form A: TV-5.
Notes ))2. Standard packing Carton: 50 pcs.; Case: 200 pcs.
Notes ))3. UL/CSA, VDE, TÜV, and SEMKO certified products can also be supported.
Notes )) Please consult us.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.