5秒后页面跳转
JC-CU-3-12-R PDF预览

JC-CU-3-12-R

更新时间: 2024-11-12 02:47:03
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
9页 343K
描述
HUB MODULE

JC-CU-3-12-R 数据手册

 浏览型号JC-CU-3-12-R的Datasheet PDF文件第2页浏览型号JC-CU-3-12-R的Datasheet PDF文件第3页浏览型号JC-CU-3-12-R的Datasheet PDF文件第4页浏览型号JC-CU-3-12-R的Datasheet PDF文件第5页浏览型号JC-CU-3-12-R的Datasheet PDF文件第6页浏览型号JC-CU-3-12-R的Datasheet PDF文件第7页 
MODEL: JC-CU  
Remote I/O JC Series  
[4] OPTIONS  
Other Options  
blank: none  
HUB MODULE  
(CUnet use)  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
EX-FACTORY SETTING  
53  
(2.09)  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9042)  
FUNCTIONS & FEATURES  
115  
(4.52)  
The HUB Module for CUnet (model: JC-CU) extends total  
length of network cable and branch cable of CUnet. Total  
max. length is 900 m when transfer rate is 3 Mbps. In order  
to connect the JC-CU, the unit configuring CUnet must  
support HUB module.  
73  
(2.87)  
mm (inch)  
GENERAL SPECIFICATIONS  
Number of port:  
MODEL: JC–CU-[1]-1[2]-[3][4]  
JC-CU-3: Trunk 1 port, feeder 2 port  
JC-CU-7: Trunk 1 port, feeder 6 port  
Max. number of inserted HUBs: 2  
(Depending on specification of CUnet I/O unit)  
Connectable devices: The products conforming to CUnet  
Connection  
ORDERING INFORMATION  
• Code number: JC-CU-[1]-1[2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. JC-CU-7-12-R/Q)  
• Specify the specification for option code /Q  
(e.g. /SET)  
Network: RJ-45 Modular Jack  
Power input: Separable tension clamp terminal  
Power on LED: PWR (green) turns on while the power is  
supplied.  
[1] I/O TYPE  
3: 3 port (trunk 1 port, feeder 2 port)  
7: 7 port (trunk 1 port, feeder 6 port)  
CUnet COMMUNICATION  
Communication mode: half-duplex  
Network cable  
TERMINAL BLOCK  
1: Tension clamp terminal block for power supply  
• Shield cable  
ZHY262PS (Shinko Seisen Industry Co., Ltd.)  
ZHT262PS (Shinko Seisen Industry Co., Ltd.)  
• Dual-shield cable  
RJ-45 Modular jack for communication  
[2] COMMUNICATION CONNECTOR PIN ASSIGNMENT  
1: 3, 4 pair wiring  
ZHY262PBA (Shinko Seisen Industry Co., Ltd.)  
Transmission distance / Transfer rate:  
Refer to the table below (Selectable with  
DIP switch. Factory default: 12 Mbps)  
Terminating resistor:  
2: 4, 5 pair wiring  
(Ethernet LAN cable pin assignment)  
Trunk built-in (Selectable with DIP switch. Factory default:  
disable)  
[3] POWER INPUT  
DC Power  
Feeder built-in  
R: 24 V DC  
Status indicator LEDs: ERR, LNK  
(Refer to the instruction manual for details)  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R5: 16 - 32 V DC  
(Operational voltage range 15 - 33 V DC, ripple 10 %p-p max.)  
JC-CU SPECIFICATIONS  
ES-9042 Rev.2 Page 1/9  
https://www.m-system.co.jp/