180W Desktop Power Supply for I.T. Equipment

ITDA180I-S120SI 数据手册

 浏览型号ITDA180I-S120SI的Datasheet PDF文件第2页 
ITDA180I SERIES  
180W Desktop Power Supply for I.T. Equipment  
Wide Input Voltage 90 to 264VAC, 47 to 63Hz  
Constant Output Voltage Available From 12VDC To 48VDC  
Over Voltage, Over Current, Short Circuit, and Over Temperature Protection  
High Efficiency (over 90%), Active Power Factor Correction (PFC)  
Energy Star 2.0, CEC Level V, and RoHS Compliance  
UL/C-UL, TUV-GS, CE Certifications  
Output connector shield connects back to earth ground.  
EMC: FCC Part 15 Class B & EN55022 Class B  
2 Year Warranty  
Approvals:  
Single Output  
Max.  
Efficiency  
Over Voltage  
Protection  
16V  
Max.  
Output Power  
170W  
Part Number  
Output Voltage  
Output Current  
14.16 A  
9.47 A  
(220VAC, Full Load)  
ITDA180I-S120SI  
ITDA180I-S190SI  
ITDA180I-S240SI  
ITDA180I-S280SI  
ITDA180I-S360SI  
ITDA180I-S480SI  
12 VDC  
19 VDC  
24 VDC  
28 VDC  
36 VDC  
48 VDC  
91.5%  
92.5%  
26V  
180W  
7.50 A  
93.5%  
33V  
180W  
6.42 A  
5.00 A  
93.5%  
39V  
180W  
93.5%  
50V  
180W  
3.75 A  
93.5%  
60V  
180W  
Electrical Characteristics  
Parameter  
Input Voltage  
Input Frequency  
Output Power Range  
Input Current (Low Line)  
Input Current (High Line)  
High Line Inrush Current  
Power Factor Correction  
Efficiency  
Test Conditions  
Min.  
90  
47  
Typ.  
Max.  
264  
63  
180  
2.3  
0.9  
50  
Unit  
VAC  
Hz  
W
A
A
A
%
%
Operating Voltage  
Vin=90 to 264VAC  
0
Io=Full load, Vin=115VAC  
Io=Full load, Vin=230VAC  
Io=Full load, 25°C, Cool start, Vin=230VAC  
Vin=110VAC  
Io=Full Load, Vin=230VAC  
No Load, VIn=230VAC  
Io=Full Load  
99  
91.5  
93.5  
0.5  
0.5  
5
No-Load Power Consumption  
Line Regulation  
Load Regulation  
W
%
%
Vin=230VAC  
Over Voltage Protection  
Over Current Protection  
Over Temperature Protection  
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.  
120  
Hiccup mode. Self-recovery when fault is removed.  
140  
125  
170  
% Io  
°C  
No damage shall occur when any output operating in a short circuit condition.  
The power supply shall be self-recovery when the fault condition is removed.  
When power on or off  
Short Circuit Protection  
Output Overshoot / Undershoot  
Start Up Time  
10  
2
%
S
Io=Full Load, Vin=90VAC  
Hold-Up Time  
Rise Time  
Fall Time  
Full Load, Vin=90~264VAC  
9
mS  
mS  
mS  
25  
30  
Full Load  
Measured by 20 MHz bandwidth oscilloscope and the  
output paralleled a 0.1 uF ceramic capacitor and a 10 uF  
electrolytic capacitor.  
Ripple & Noise (Peak to Peak)  
1.5  
% Vo  
Conditions  
Parameter  
Operating Temperature  
Storage Temperature  
Test Conditions  
Humidity: 10% RH to 90% RH  
Humidity: 5% RH to 95% RH  
Min.  
0
-20  
Typ.  
Max.  
+40  
80  
Unit  
°C  
°C  
Operation temperature at 25°C, calculated per MIL-HDBK-217F  
0.45M  
Hours  

与ITDA180I-S120SI相关器件

型号 品牌 描述 获取价格 数据表
ITDA180I-S190SI Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格

ITDA180I-S240SI Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格

ITDA180I-S280SI Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格

ITDA180I-S360SI Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格

ITDA180I-S480SI Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格

ITDA180I-SERIES Vitec 180W Desktop Power Supply for I.T. Equipment

获取价格