APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO +85C
-10C TO +60C
TEMPERATURE RANGE
TEMPERATURE RANGE
OPERATING
HUMIDITY RANGE
RELATIVE HUMIDITY:90% MAX
(NO DEW CONDENSATION IS PERMITTED)
VOLTAGE
RATING
AC 50V
SIGNAL: 0.5A
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUAL AND WITH MEASURING INSTRUMENT
CONFIRM VISUALLY
ACCORDING TO A DRAWING
X
X
X
MARKING
X
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
[EIA-364-23]
100mA
50m MAX (*1) (HEGHT:10 ~ 19mm)
60m MAX (*1) (HEGHT:20 ~ 29mm)
70m MAX (*1) (HEGHT:30 ~ 39mm)
80m MAX (*1) (HEGHT:40 ~ 46mm)
1000M MIN
X
―
INSULATION RESISTANCE 100V DC
[EIA-364-21]
X
X
―
―
VOLTAGE PROOF
[EIA-364-20]
150V AC FOR 1 min
NO FLASHOVER OR BREAKDOWN
MECHANICAL CHARACTERISTICS
INSERTION AND WITHDRAWAL
MEASURED WITH RESPECT TO
APPLICABLE CONNECTORS
INSERTION FORCE:
WITHDRAWAL FORCE:
135N MAX
10N MIN
1
X
X
―
―
FORCES [EIA-364-13]
MECHANICAL OPERATION 100 TIMES INSERTION AND EXTRACTION
[EIA-364-09]
1) CONTACT RESISTANCE CHANGE:20m
OR LESS
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
RANDOM VIBRATION
[EIA-364-28]
FREQUENCY:50 TO 2000Hz
1) NO ELECTRICAL DISCONTINUITY OF
1s OR MORE
2) NO DAMAGE, CRACK OR LOOSENESS
POWER SPECTRAL DENSITY:0.1G2/Hz
FOR 120 min IN 3 DIRECTIONS
―
―
X
X
SHOCK
[EIA-364-27]
490m/s2, DURATION OF PULSE:11ms
18 TIMES TOTAL, 3 EACH DIRECTION, 3 AXIS
OF PARTS
ENVIRONMENTAL CHARACTERISTICS
THERMAL SHOCK
[EIA-364-32]
TEMPERATURE(C): -65 →20 ~ 35 → 105 →20 ~ 35
1) CONTACT RESISTANCE CHANGE:20m
OR LESS
TIME(min):
30 → 5MAX → 30 → 5MAX
X
X
―
―
UNDER 25 CYCLES
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
CYCLIC TEMPERATURE
AND HUMIDITY
[EIA-364-31]
@ 25C, 80% RH:60 min DWELL TIME
30 min RAMP TIME
↓
@ 65C, 50% RH:60 min DWELL TIME
UNDER 24 CYCLES
DRY HEAT
[EIA-364-17]
EXPOSED AT 105C, 120 HOURS
1) CONTACT RESISTANCE CHANGE:20m
OR LESS
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
X
―
MIXED FLOWING GAS
[EIA-364-65]
EXPOSED AT 30C, 70% RH
Cl2:10ppb, NO2:200ppb, H2S:10ppb, SO2:100ppb
UNMATED 7 DAYS → MATED 7 DAYS
CONTACT RESISTANCE CHANGE:20m
OR LESS
X
X
―
―
REFLOW TEMPERATURE
CONDITION
[IPC/JEDEC STD-020]
NO BLISTER OR EVIDENCE OF MELTING
PRECONDITION AT 60C, 60% RH FOR 120 HOURS
REFLOW PEAK TEMPERATURE:260C AT
CONNETOR SURFACE
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
1
1
DIS-F-00003665
TH.SANO
MK.EZAKI
MK.EZAKI
YS.TAKEUCHI
TH.SANO
18.08.09
16.04.15
16.04.15
16.04.15
16.04.15
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
(*1) THE VALUE OF CONTACT RESISTANCE INCLUDES THE BULK RESISTANCE.
TH.SANO
NOTE QT: QUALIFICATION TEST; AT: ASSURANCE TEST; X: APPLICATION TEST
ELC-355936-00-00
IT8D-192P-BGA-0H
CL636-3201-8-00
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
1
1/1