APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-55 C TO +85 C
-10 C TO +60 C
TEMPERATURE RANGE
OPERATING
HUMIDITY RANGE
RELATIVE HUMIDITY: 90% MAX
(NO DEW CONDENSATION IS PERMITTED)
RATING
VOLTAGE
AC 50 V
SIGNAL: 0.2A
POWER: REFER TO TEST REPORT TR636E-20041 AND TR636E-20282 FOR SPECIFIC POWER APPLICATIONS
OR CONTACT HIROSE.
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUAL AND WITH MEASURING INSTRUMENT
CONFIRM VISUALLY
ACCORDING TO A DRAWING
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA
MATED WITH IT5**-200P-H(**)
[EIA-364-23]
60 m MAX (*1) (HEGHT: 18~20mm)
70 m MAX (*1) (HEGHT: 22~24 mm)
80 m MAX (*1) (HEGHT: 25~28 mm)
90 m MAX (*1) (HEGHT: 29~32 mm)
100 m MAX (*1) (HEGHT: 33~36 mm)
110 m MAX (*1) (HEGHT: 37~40 mm)
MATED WITH IT3**-200P-H(**)
X
X
50 m MAX (*1) (HEGHT: 17 ~ 24 mm)
55 m MAX (*1) (HEGHT: 25 ~ 32 mm)
60 m MAX (*1) (HEGHT: 33 ~ 40 mm)
INSULATION RESISTANCE 100 V DC
[EIA-364-21]
1000 M MIN
X
X
―
VOLTAGE PROOF
[EIA-364-20]
150 V AC FOR 1 min
NO FLASHOVER OR BREAKDOWN
X
MECHANICAL CHARACTERISTICS
INSERTION AND WITHDRAWAL
MEASURED WITH RESPECT TO
INSERTION FORCE:
FORCES [EIA-364-13]
APPLICABLE CONNECTORS
180 N MAX (including locking power)
X
X
―
―
1
△
WITHDRAWAL FORCE:
10 N MIN
MECHANICAL OPERATION 100 TIMES INSERTION AND EXTRACTION
[EIA-364-09]
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
RANDOM VIBRATION
[EIA-364-28]
FREQUENCY: 50 TO 2000 Hz
1) NO ELECTRICAL DISCONTINUITY OF
1s OR MORE
2) NO DAMAGE, CRACK OR LOOSENESS
POWER SPECTRAL DENSITY: 0.1 G2/Hz
FOR 90 min IN THREE DIRECTIONS
490 m/s2, DURATION OF PULSE: 11 ms
18 TIMES TOTAL, 3 EACH DIRECTION, 3 AXIS
X
X
―
―
SHOCK
[EIA-364-27]
OF PARTS
ENVIRONMENTAL CHARACTERISTICS
THERMAL SHOCK
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
TEMPERATURE(C): -55 →20 ~ 35 → 85 →20 ~ 35
[EIA-364-32]
TIME(min):
30 → 5MAX → 30 → 5MAX
X
X
―
―
UNDER 10 CYCLES
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
CYCLIC TEMPERATURE
AND HUMIDITY
[EIA-364-31]
@ 25 C, 80% RH: 60 min DWELL TIME
30 min RAMP TIME
↓
@ 65 C, 50% RH: 60 min DWELL TIME
UNDER 24 CYCLES
DRY HEAT
[EIA-364-17]
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
2) NO DAMAGE, CRACK OR LOOSENESS
EXPOSED AT 105 C, 120 HOURS
X
―
OF PARTS
MIXED FLOWING GAS
[EIA-364-65]
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
2) NO HEAVY CORROSION
EXPOSED AT 30 C, 70% RH
Cl2 : 10 ppb, NO2 : 200 ppb, H2S : 10 ppb, SO2 : 100 ppb
X
X
―
―
UNMATED 7 DAYS → MATED 7 DAYS
REFLOW TEMPERATURE
CONDITION
[IPC / JEDEC STD-020]
PRECONDITION AT 60 C, 60% RH FOR 120 hr
REFLOW PEAK TEMPERATURE : 260 C AT
CONNETOR SURFACE
NO BLISTER OR EVIDENCE OF MELTING
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
AS.MATSUZAWA
CHECKED
DATE
1
1
DIS-F-00004006
MK.EZAKI
20181207
20131113
20131113
20131112
20131112
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
MK.EZAKI
(*1) THE VALUE OF CONTACT RESISTANCE INCLUDES 2 CONTACT POINTS AND THE BULK
MK.EZAKI
RESISTANCE.
(*2) REFER TO TEST REPORT TR636E-10259 AND TR636E-10258 FOR FULL ELECTRICAL
CHARACTERISTICS,MECHANICAL CHARACTERISTICS AND ENVIRONMENTAL
CHARACTERISTICS TESTS AND RESULTS.
TF.SUGAWARA
TF.SUGAWARA
NOTE -- QT: QUALIFICATION TEST; AT: ASSURANCE TEST; X: APPLICATION TEST
DRAWING NO.
ELC4-343336-01
IT5HM-200S-BGA(37)
CL636-1524-6-37
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC (U.S.A.), INC.
1/1
1
FORM HD0011-2-1