APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
OPERATING
-55C TO 85C
-10C TO +60C
RELATIVE HUMIDITY : 90 % MAX
TEMPERATURE RANGE
RATING VOLTAGE
CURRENT
AC 50V
(NO DEW CONDENSATION IS PERMITTED)
HUMIDITY RANGE
SIGNAL:0.5A/PIN
POWER: REFER TO IT3 DERATING CURVES FROM TEST REPORTS TR636E-20041 FOR POWER APPLICATION
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND WITH MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO A DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz).
50 m MAX( *) (HEIGHT:17 ~ 24 mm)
55 m MAX( *) (HEIGHT:25 ~ 32 mm)
X
X
60 m MAX( *) (HEIGHT:33 ~ 40 mm)
MATED WITH IT3-100P-**H(**).
INSULATION RESISTANCE
VOLTAGE PROOF
100 V DC.
1000
M MIN.
X
X
-
150 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
X
MECHANICAL CHARACTERISTICS
INSERTION AND
MEASURED WITH APPLICABLE CONNECTOR.
INSERTION FORCE:
WITHDRAWAL FORCES
120.0 N MAX(including locking power).
WITHDRAWAL FORCE: 5.0 N MIN.
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS.
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
X
X
-
-
1
△
MECHANICAL OPERATION
100 TIMES INSERTIONS AND EXTRACTIONS.
VIBRATION
SHOCK
FREQUENCY: 10 TO 55 Hz.
1) NO ELECTRICAL DISCONTINUITY OF
1s OR MORE.
2) NO DAMAGE, CRACK OR LOOSENESS
X
X
SINGLE AMPLITUDE: 0.75 mm,
FOR 10 CYCLES IN 3 DIRECTIONS.
490 m/s2, DURATION OF PULSE: 11 ms.
FOR 3 TIMES IN 3 DIRECTIONS.
-
-
OF PARTS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS.
EXPOSED AT 40 ℃, 90 TO 95 %, 96 hr.
X
X
(STEADY STATE)
-
-
RAPID CHANGE OF
TEMPERATURE
2)INSULATION RESISTANCE: 100 M MIN.
3) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
TEMPERATURE –55 →15 TO 35→85→15 TO 35 C.
TIME
30 → 2 TO 3 →30 →2 TO 3 min.
UNDER 5 CYCLES.
DRY HEAT
1)CONTACT RESISTANCE CHANGE:
20 m OR LESS.
2)NO DAMAGE, CRACK OR LOOSENESS
OF PART.
EXPOSED AT
85 ℃,
-55 ℃,
96 hr.
96 hr.
X
X
X
X
-
-
-
-
COLD
EXPOSED AT
CORROSION SALT MIST
EXPOSED IN 5 % SALT WATER SPRAY FOR 48
hr.
1)CONTACT RESISTANCE CHANGE:
20 m OR LESS.
2)NO HEAVY CORROSION.
SULPHUR DIOXIDE
(TEST STANDARD:JIS C
0090)
EXPOSED IN 25±5 PPM FOR 96 hr AT 40℃,
Relative Humidity 80±5%.
RESISTANCE TO
SOLDERING HEAT
RECOMMENDED TEMPERATURE FOR REFLOW
NO MELTING OF RESIN WHICH AFFECTS
THE PERFORMANCE OF COMPONENT.
X
・PEAK TEMP.
:260℃ AT CONNECTOR
-
SURFACE, FOR 5 s MAX
・REFLOW TEMP.
・SOAK TEMP.
:230℃ - 250℃
FOR 45 s - 120 s
:160℃ - 215℃
FOR
0 s - 120 s
* REFLOW SOLDERING IS ACCEPTABLE UP TO TWICE.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
AS.MATSUZAWA
CHECKED
DATE
△
1
DIS-F-00004006
MK.EZAKI
20181207
1
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
TM.MATSUO
20170511
20170511
20170511
20170511
(*)THE VALUE OF CONTACT RESISTANCE INCLUDES 2 CONTACT POINTS AND
THE BULK RESISTANCE.
MK.EZAKI
KT.AIZAWA
KT.AIZAWA
Unless otherwise specified, refer to JIS C 5402(IEC-60512).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-157286-37-00
PART NO.
CODE NO.
IT3M-100S-BGA(37)
CL636-0014-4-37
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1/1
1
△
FORM HD0011-2-1