APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
STORAGE
TEMPERATURE RANGE
-40 C TO +65 C
-10 C TO +60 C
RELATIVE HUMIDITY: 90% MAX
(NO DEW CONDENSATION IS
PERMITTED)
OPERATING
HUMIDITY RANGE
RATING
VOLTAGE
CURRENT
AC/DC 29.9 V
1A (*1)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUAL AND WITH MEASURING INSTRUMENT
CONFIRM VISUALLY
ACCORDING TO A DRAWING
X
X
X
X
ELECTRIC CHARACTERISTICS
20 m MAX (*1,2)
CONTACT RESISTANCE
[EIA-364-23]
100 mA
X
X
X
―
―
INSULATION RESISTANCE 100 V DC
[EIA-364-21]
1000 M MIN
VOLTAGE PROOF
[EIA-364-20]
500 V AC FOR 1 min
NO FLASHOVER OR BREAKDOWN
―
MECHANICAL CHARACTERISTICS
INSERTION AND
MEASURED BY APPLICABLE CONNECTOR.
INSERTION FORCE: 39 N MAX
WITHDRAWAL FORCE: 3 N MIN
WITHDRAWAL FORCES
X
X
―
―
[EIA-364-13]
MECHANICAL OPERATION 25TIMES INSERTION AND EXTRACTION
[EIA-364-09]
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
RANDOM VIBRATION
[EIA-364-28]
FREQUENCY: 20 TO 500 Hz
1) NO ELECTRICAL DISCONTINUITY OF
1s OR MORE
2) NO DAMAGE, CRACK OR LOOSENESS
POWER SPECTRAL DENSITY: 0.02 G2/Hz
FOR 60 min IN THREE DIRECTIONS
490 m/s2, DURATION OF PULSE: 11 ms
18 TIMES TOTAL, 3 EACH DIRECTION, 3 AXIS
X
X
―
―
OF PARTS
SHOCK
[EIA-364-27]
ENVIRONMENTAL CHARACTERISTICS
THERMAL SHOCK
[EIA-364-32]
TEMPERATURE(C): -55 →20 ~ 35 → 85 →20 ~ 35
TIME(min): 30 → 5MAX → 30 → 5MAX
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
X
X
―
―
UNDER 10 CYCLES
@ 25 C, 90-95% RH: 120 min DWELL TIME
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
CYCLIC TEMPERATURE
AND HUMIDITY
[EIA-364-31]
↓
120 min RAMP TIME
@ 65 C, 90-95% RH: 120 min DWELL TIME
UNDER 60 CYCLES
DRY HEAT
[EIA-364-17]
EXPOSED AT 105C, 300 HOURS
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
X
―
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
DUST
UNMATED 1 HOUR
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
1) CONTACT RESISTANCE CHANGE:
20 m OR LESS
2) NO HEAVY CORROSION
X
X
―
―
[EIA-364-91]
MIXED FLOWING GAS
[EIA-364-65]
EXPOSED AT 30 C, 70% RH
Cl2 : 10 ppb, NO2 : 200 ppb, H2S : 10 ppb, SO2 : 100 ppb
MATED 10 DAYS
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
APPROVED
CHECKED
DESIGNED
DRAWN
TM.MATSUO
20181212
20181211
20181211
20181211
REMARK
MK.EZAKI
(*1)SPECIFICATION WHEN MATED WITH CARD EDGH BOARD
(*2)THE VALUE OF CONTACT RESISTANCE INCLUDES THE BULK RESISTANCE
XINGYU CHENG
XINGYU CHENG
NOTE -- QT: QUALIFICATION TEST; AT: ASSURANCE TEST; X: APPLICATION TEST
DRAWING NO.
PART NO.
ELC-378490-00-01
IT12M1-60S-0.8SV
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0 1/1
CODE NO.
CL636-5001-0-00
FORM HD0011-2-1