APPLICABLE STANDARD
OPERATING
STORAGE
(1) (2)
(3)
-55 C TO +85 C
-10 C TO +60 C
TEMPERATURE RANGE
OPERATING HUMIDITY
TEMPERATURE RANGE
STORAGE HUMIDITY
RANGE
(2) (4)
(3) (4) (6)
RATING
RH 90 % MAX
RH 70 % MAX
RANGE
VOLTAGE
CURRENT
1
△
300 V DC/AC
60A (TEMPERATURE RISE 30C MAX)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUAL AND WITH MEASURING INSTRUMENT
ACCORDING TO DRAWING
×
×
×
×
MARKING
CONFIRMED VISUALLY
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE 10 mA
[EIA-364-23]
2 mΩMAX.(5)
MATED WITH IT-PB-2S-DIRL**
-
×
INSULATION RESISTANCE
[EIA-364-21]
-
-
500 V DC
1000 MΩMIN.
×
×
VOLTAGE PROOF
[EIA-364-20]
1000 V AC FOR 1 MINUTE
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
INSERTION AND
WITHDRAWAL FORCES CONNECTORS
[EIA-364-13]
MEASURED WITH RESPECT TO APPLICABLE
INSERTION FORCE:
50 N MAX.
N MIN.
WITHDRAWAL FORCE:
3
-
-
×
×
(mated with IT-PB-2S-DIRL**)
① CONTACT RESISTANCE: 2 mΩ MAX. (5)
② NO DAMAGE, CRACKS, OR LOOSE PARTS
MECHANICAL
OPERATION
[EIA-364-09]
100 TIMES INSERTION AND EXTRACTION
RANDOM VIBRATION
[EIA-364-28]
FREQUENCY : 50 TO 2000 Hz
① NO ELECTRICAL DISCONTINUITY OF 1 s OR
MORE
POWER SPECTRAL DENSITY : 0.1 g2/Hz
FOR 90 MINUTES IN THREE DIRECTIONS
*Spacers were used to maintain the distance between the
PCB’s during testing.
② NO DAMAGE, CRACKS, OR LOOSE PARTS
-
-
×
×
SHOCK
[EIA-364-27]
490 m/s2 , DURATION OF PULSE : 11 ms
18 TIMES TOTAL , 3 EACH DIRECTION , 3 AXIS
*Spacers were used to maintain the distance between the
PCB’s during testing.
ENVIRONMENTAL CHARACTERISTICS
THERMAL SHOCK
TEMPERATURE: -55 →20 ~ 35 → 85 →20 ~ 35 C
① CONTACT RESISTANCE : 2 mΩ MAX. (5)
② INSULATION RESISTANCE : 100 M MIN.
③ NO DAMAGE, CRACKS, OR LOOSE PARTS
[EIA-364-32]
TIME:
30 → 5 MAX → 30 → 5 MAX minutes
10 CYCLES
-
CYCLIC TEMPERATURE @ 25 C, 80% RH: 60 MIN DWELL TIME
×
AND HUMIDITY
[EIA-364-31]
30 MIN RAMP TIME
@ 65 C, 50% RH: 60 MIN DWELL TIME
24 CYCLES
DRY HEAT
[EIA-364-17]
EXPOSED AT 105 C, 120 hr
① CONTACT RESISTANCE : 2 mΩ MAX. (5)
② NO DAMAGE, CRACKS, OR LOOSE PARTS
CONTACT RESISTANCE : 2 mΩMAX. (5)
-
-
×
×
MIXED FLOWING GAS
[EIA-364-65]
EXPOSED AT 30 C, 70%
Cl2 : 10 ppb, NO2 : 200 ppb, H2S : 10 ppb, SO2 : 100 ppb
UNMATED 7 DAYS, MATED 7 DAYS
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
TH.SANO
CHECKED
DATE
1
1
DIS-F-00020361
TY.TAKADA
20240508
△
REMARKS
APPROVED
CHECKED
DESIGNED
MK.EZAKI
MK.EZAKI
20151203
20151203
20151203
(1) INCLUDE TEMPERATURE RISE CAUSED BY CURRENT-CARRYING.
(2) OPERATING TEMPERATURE SHOULD BE -55 TO 55℃ WHEN HUMIDITY EXCEEDS 80% RH.
(3) “STORAGE” MEANS A LONG-TERM STORAGE STATE FOR THE UNUSED PRODUCT IN SEALED BAGS
BEFORE ASSEMBLY TO PCB.
(4) NO DEW CONDENSATION IS PERMITTED.
(5) THE VALUE OF CONTACT RESISTANCE INCLUDES 2 CONTACT POINTS AND THE BULK RESISTANCE.
(6) THIS APPLIES TO SEALED PLASTIC BAGS. OPEN BAGS MUST BE PROTECTED FROM MOISTURE,
SULFUR, AND CHLORIDE WHICH CAN CAUSE THE SILVER PLATING TO TARNISH.
NY.SHIMURA
(7) THE TEST ITEM WHICH IS NOT DESCRIBED HEREIN SHALL BE COME FROM IEC-60512 (JIS C 5402).
DRAWN
NY.SHIMURA
20151203
Note; QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-364206-11-00
IT-PB-2P-11H(11)
PART NO.
CODE NO.
SPECIFICATION SHEET
1
△
1/1
HIROSE ELECTRIC CO., LTD.
CL0636-0633-0-11
FORM HD0011-2-1