APPLICABLE STANDARD
OPERATING
STORAGE
-10 C TO +60 C (3)
RH 70 % MAX (3) (4) (6)
-55 C TO +85 C (1) (2)
RH 90 % MAX (2) (4)
300 V DC/AC
TEMPERATURE RANGE
OPERATING HUMIDITY
RANGE
TEMPERATURE RANGE
STORAGE HUMIDITY
RANGE
RATING
VOLTAGE
CURRENT
60A (TEMPERATURE RISE 30℃ MAX)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUAL AND WITH MEASURING INSTRUMENT
ACCORDING TO DRAWING
×
×
×
×
MARKING
CONFIRMED VISUALLY
ELECTRIC CHARACTERISTICS
100 mA AND 20 mV OPEN CIRCUIT MAX.
2 mΩMAX.(5)
CONTACT RESISTANCE
MATED WITH IT-PM-2S-DIR
IT-PD-2S-DIR
[EIA-364-23]
-
-
-
×
INSULATION RESISTANCE
[EIA-364-21]
500 V DC
1000 MΩMIN.
×
×
VOLTAGE PROOF
[EIA-364-20]
1000 V AC FOR 1 MINUTE
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MEASURED WITH RESPECT TO APPLICABLE
INSERTION FORCE:
50 N MAX.
N MIN.
INSERTION AND
WITHDRAWAL FORCES
[EIA-364-13]
CONNECTORS
WITHDRAWAL FORCE: 3
-
-
×
×
100 TIMES INSERTION AND EXTRACTION
① CONTACT RESISTANCE: 2 mΩ MAX. (5)
② NO DAMAGE, CRACKS, OR LOOSE PARTS
MECHANICAL
OPERATION
[EIA-364-09]
FREQUENCY : 50 TO 2000 Hz
① NO ELECTRICAL DISCONTINUITY OF 1 s OR
MORE
RANDOM VIBRATION
[EIA-364-28]
POWER SPECTRAL DENSITY : 0.1 g2/Hz
FOR 90 MINUTES IN THREE DIRECTIONS
*Spacers were used to maintain the distance between the
PCB’s during testing.
② NO DAMAGE, CRACKS, OR LOOSE PARTS
-
-
×
×
490 m/s2 , DURATION OF PULSE : 11 ms
18 TIMES TOTAL , 3 EACH DIRECTION , 3 AXIS
*Spacers were used to maintain the distance between the
PCB’s during testing.
SHOCK
[EIA-364-27]
ENVIRONMENTAL CHARACTERISTICS
TEMPERATURE: -55 →20 ~ 35 → 85 →20 ~ 35 C
① CONTACT RESISTANCE : 2 mΩ MAX. (5)
② INSULATION RESISTANCE : 100 M MIN.
③ NO DAMAGE, CRACKS, OR LOOSE PARTS
THERMAL SHOCK
TIME:
30 → 5 MAX → 30 → 5 MAX minutes
[EIA-364-32]
10 CYCLES
@ 25 C, 80% RH: 60 MIN DWELL TIME
30 MIN RAMP TIME
CYCLIC TEMPERATURE
AND HUMIDITY
[EIA-364-31]
×
-
@ 65 C, 50% RH: 60 MIN DWELL TIME
24 CYCLES
EXPOSED AT 105 C, 120 hr
① CONTACT RESISTANCE : 2 mΩ MAX. (5)
② NO DAMAGE, CRACKS, OR LOOSE PARTS
CONTACT RESISTANCE: 2 mΩMAX. (5)
DRY HEAT
[EIA-364-17]
-
-
×
×
EXPOSED AT 30 C, 70%
Cl2 : 10 ppb, NO2 : 200 ppb, H2S : 10 ppb, SO2 : 100 ppb
UNMATED 7 DAYS, MATED 7 DAYS
MIXED FLOWING GAS
[EIA-364-65]
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARKS
APPROVED
CHECKED
DESIGNED
MK.EZAKI
MK.NAGATA
NY.SHIMURA
16.06.22
16.06.22
16.06.22
(1) INCLUDE TEMPERATURE RISE CAUSED BY CURRENT-CARRYING.
(2) OPERATING TEMPERATURE SHOULD BE -55 TO 55℃ WHEN HUMIDITY EXCEEDS 80% RH.
(3) “STORAGE” MEANS A LONG-TERM STORAGE STATE FOR THE UNUSED PRODUCT IN SEALED BAGS
BEFORE ASSEMBLY TO PCB.
(4) NO DEW CONDENSATION IS PERMITTED.
(5) THE VALUE OF THE CONTACT RESISTANCE INCLUDES 2 CONTACT POINTS AND THE BULK RESISTANCE.
(6) THIS APPLIES TO SEALED PLASTIC BAGS. OPEN BAGS MUST BE PROTECTED FROM MOISTURE,
SULFUR, AND CHLORIDE WHICH CAN CAUSE THE SILVER PLATING TO TARNISH.
(7) TEST ITEMS WHICH ARE NOT DESCRIBED HEREIN SHALL FOLLOW IEC-60512 (JIS C 5402).
DRAWN
NY.SHIMURA
16.06.22
Note: QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
ELC-357296-11-00
IT-P-2P-21H(11)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CODE NO.
CL636-0618-2-11