ISO1050
www.ti.com
SLLS983H –JUNE 2009–REVISED JUNE 2013
ISOLATED CAN TRANSCEIVER
Check for Samples: ISO1050
1
FEATURES
•
•
•
•
•
•
•
•
•
Meets the Requirements of ISO11898-2
5000-VRMS Isolation (ISO1050DW)
2500-VRMS Isolation (ISO1050DUB)
Failsafe Outputs
•
•
I/O Voltage Range Supports 3.3V and 5V
Microprocessors
Typical 25-Year Life at Rated Working Voltage
(see Application Report SLLA197 and
Figure 18)
Low Loop Delay: 150ns (Typ), 210ns (Max)
50 kV/μs Typical Transient Immunity
Bus-Fault Protection of –27 V to 40 V
Driver (TXD) Dominant Time Out Function
APPLICATIONS
•
Industrial Automation, Control, Sensors and
Drive Systems
IEC 60747-5-2 (VDE 0884, Rev. 2) and
IEC 61010-1 Approved
•
Building and Climate Control (HVAC)
Automation
•
UL 1577 Double Protection Approved; See
Regulatory Information Section
•
•
•
•
•
Security Systems
Transportation
Medical
•
•
IEC 60601-1 (Medical) and CSA Approved
5 KVRMS Reinforced Insulation per TUV
Approved for EN/UL/CSA 60950-1
(ISO1050DW)
Telecom
CAN Bus Standards Such as CANopen,
DeviceNet, NMEA2000, ARINC825, ISO11783,
CAN Kingdom, CANaerospace
DESCRIPTION
The ISO1050 is a galvanically isolated CAN transceiver that meets the specifications of the ISO11898-2
standard. The device has the logic input and output buffers separated by a silicon oxide (SiO2) insulation barrier
that provides galvanic isolation of up to 5000 VRMS for ISO1050DW and 2500 VRMS for ISO1050DUB. Used in
conjunction with isolated power supplies, the device prevents noise currents on a data bus or other circuits from
entering the local ground and interfering with or damaging sensitive circuitry.
As a CAN transceiver, the device provides differential transmit capability to the bus and differential receive
capability to a CAN controller at signaling rates up to 1 megabit per second (Mbps). Designed for operation in
especially harsh environments, the device features cross-wire, overvoltage and loss of ground protection from
–27 V to 40 V and over-temperature shut-down, as well as –12 V to 12 V common-mode range.
The ISO1050 is characterized for operation over the ambient temperature range of –55°C to 105°C.
DW PACKAGE
DUB PACKAGE
FUNCTION DIAGRAM
1
VCC2
1
2
3
4
5
6
7
8
VCC2
GND2
nc
VCC1
RXD
VCC1
GND1
RXD
nc
16
15
14
13
12
11
10
9
8
RXD
TXD
2
3
4
CANH
CANL
GND2
7
6
5
TXD
CANH
CANL
GND1
CANH
CANL
nc
nc
TXD
GND1
GND1
GND2
GND2
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.